| 1 | table | index | column | value |
|---|
| 2 | interfaces | 1 | ifDescr | EVEN_VLAN_UPLINK |
| 3 | interfaces | 1 | ifType | ethernetCsmacd |
| 4 | interfaces | 1 | ifMtu | 4096 |
| 5 | interfaces | 1 | ifSpeed | 1000000000 |
| 6 | interfaces | 1 | ifPhysAddress | 0:15:ad:47:3e:61 |
| 7 | interfaces | 1 | ifAdminStatus | up |
| 8 | interfaces | 1 | ifOperStatus | up |
| 9 | interfaces | 1 | ifInOctets | 4226334873 |
| 10 | interfaces | 1 | ifInDiscards | 0 |
| 11 | interfaces | 1 | ifInErrors | 0 |
| 12 | interfaces | 1 | ifOutOctets | 2379524702 |
| 13 | interfaces | 1 | ifOutDiscards | 0 |
| 14 | interfaces | 1 | ifOutErrors | 0 |
| 15 | interfaces | 1 | ifName | EVEN_VLAN_UPLINK |
| 16 | interfaces | 1 | ifHCInOctets | 12816269465 |
| 17 | interfaces | 1 | ifHCOutOctets | 15264426590 |
| 18 | interfaces | 1 | ifHighSpeed | 1000 |
| 19 | interfaces | 2 | ifDescr | ODD_VLAN_UPLINK |
| 20 | interfaces | 2 | ifType | ethernetCsmacd |
| 21 | interfaces | 2 | ifMtu | 4096 |
| 22 | interfaces | 2 | ifSpeed | 0 |
| 23 | interfaces | 2 | ifPhysAddress | 0:15:ad:47:3e:62 |
| 24 | interfaces | 2 | ifAdminStatus | up |
| 25 | interfaces | 2 | ifOperStatus | down |
| 26 | interfaces | 2 | ifInOctets | 135053161 |
| 27 | interfaces | 2 | ifInDiscards | 0 |
| 28 | interfaces | 2 | ifInErrors | 0 |
| 29 | interfaces | 2 | ifOutOctets | 110445216 |
| 30 | interfaces | 2 | ifOutDiscards | 0 |
| 31 | interfaces | 2 | ifOutErrors | 0 |
| 32 | interfaces | 2 | ifName | ODD_VLAN_UPLINK |
| 33 | interfaces | 2 | ifHCInOctets | 135053161 |
| 34 | interfaces | 2 | ifHCOutOctets | 110445216 |
| 35 | interfaces | 2 | ifHighSpeed | 0 |
| 36 | interfaces | 3 | ifDescr | EVEN_VLAN_DOWNLIN |
| 37 | interfaces | 3 | ifType | ethernetCsmacd |
| 38 | interfaces | 3 | ifMtu | 2000 |
| 39 | interfaces | 3 | ifSpeed | 0 |
| 40 | interfaces | 3 | ifPhysAddress | 0:15:ad:47:3e:63 |
| 41 | interfaces | 3 | ifAdminStatus | up |
| 42 | interfaces | 3 | ifOperStatus | down |
| 43 | interfaces | 3 | ifInOctets | 2194071425 |
| 44 | interfaces | 3 | ifInDiscards | 0 |
| 45 | interfaces | 3 | ifInErrors | 0 |
| 46 | interfaces | 3 | ifOutOctets | 3499102118 |
| 47 | interfaces | 3 | ifOutDiscards | 0 |
| 48 | interfaces | 3 | ifOutErrors | 0 |
| 49 | interfaces | 3 | ifName | EVEN_VLAN_DOWNLIN |
| 50 | interfaces | 3 | ifHCInOctets | 15078973313 |
| 51 | interfaces | 3 | ifHCOutOctets | 12089036710 |
| 52 | interfaces | 3 | ifHighSpeed | 0 |
| 53 | interfaces | 4 | ifDescr | ODD_VLAN_DOWNLINK |
| 54 | interfaces | 4 | ifType | ethernetCsmacd |
| 55 | interfaces | 4 | ifMtu | 4096 |
| 56 | interfaces | 4 | ifSpeed | 0 |
| 57 | interfaces | 4 | ifPhysAddress | 0:15:ad:47:3e:64 |
| 58 | interfaces | 4 | ifAdminStatus | up |
| 59 | interfaces | 4 | ifOperStatus | down |
| 60 | interfaces | 4 | ifInOctets | 314336220 |
| 61 | interfaces | 4 | ifInDiscards | 0 |
| 62 | interfaces | 4 | ifInErrors | 0 |
| 63 | interfaces | 4 | ifOutOctets | 354824130 |
| 64 | interfaces | 4 | ifOutDiscards | 0 |
| 65 | interfaces | 4 | ifOutErrors | 0 |
| 66 | interfaces | 4 | ifName | ODD_VLAN_DOWNLINK |
| 67 | interfaces | 4 | ifHCInOctets | 314336220 |
| 68 | interfaces | 4 | ifHCOutOctets | 354824130 |
| 69 | interfaces | 4 | ifHighSpeed | 0 |
| 70 | interfaces | 5 | ifDescr | Management |
| 71 | interfaces | 5 | ifType | ethernetCsmacd |
| 72 | interfaces | 5 | ifMtu | 2000 |
| 73 | interfaces | 5 | ifSpeed | 100000000 |
| 74 | interfaces | 5 | ifPhysAddress | 0:15:ad:47:3e:65 |
| 75 | interfaces | 5 | ifAdminStatus | up |
| 76 | interfaces | 5 | ifOperStatus | up |
| 77 | interfaces | 5 | ifInOctets | 1804049253 |
| 78 | interfaces | 5 | ifInDiscards | 0 |
| 79 | interfaces | 5 | ifInErrors | 0 |
| 80 | interfaces | 5 | ifOutOctets | 1440652753 |
| 81 | interfaces | 5 | ifOutDiscards | 0 |
| 82 | interfaces | 5 | ifOutErrors | 0 |
| 83 | interfaces | 5 | ifName | Management |
| 84 | interfaces | 5 | ifHCInOctets | 134948035429 |
| 85 | interfaces | 5 | ifHCOutOctets | 1440652753 |
| 86 | interfaces | 5 | ifHighSpeed | 100 |
| 87 | interfaces | 6 | ifDescr | LAG-1 |
| 88 | interfaces | 6 | ifType | ethernetCsmacd |
| 89 | interfaces | 6 | ifMtu | 10240 |
| 90 | interfaces | 6 | ifSpeed | 0 |
| 91 | interfaces | 6 | ifPhysAddress | 0:15:ad:47:3e:61 |
| 92 | interfaces | 6 | ifAdminStatus | up |
| 93 | interfaces | 6 | ifOperStatus | down |
| 94 | interfaces | 6 | ifInOctets | 0 |
| 95 | interfaces | 6 | ifInDiscards | 0 |
| 96 | interfaces | 6 | ifInErrors | 0 |
| 97 | interfaces | 6 | ifOutOctets | 0 |
| 98 | interfaces | 6 | ifOutDiscards | 0 |
| 99 | interfaces | 6 | ifOutErrors | 0 |
| 100 | interfaces | 6 | ifName | LAG-1 |
| 101 | interfaces | 6 | ifHCInOctets | 0 |
| 102 | interfaces | 6 | ifHCOutOctets | 0 |
| 103 | interfaces | 6 | ifHighSpeed | 0 |
| 104 | interfaces | 7 | ifDescr | LAG-2 |
| 105 | interfaces | 7 | ifType | ethernetCsmacd |
| 106 | interfaces | 7 | ifMtu | 10240 |
| 107 | interfaces | 7 | ifSpeed | 0 |
| 108 | interfaces | 7 | ifPhysAddress | 0:15:ad:47:3e:63 |
| 109 | interfaces | 7 | ifAdminStatus | up |
| 110 | interfaces | 7 | ifOperStatus | down |
| 111 | interfaces | 7 | ifInOctets | 0 |
| 112 | interfaces | 7 | ifInDiscards | 0 |
| 113 | interfaces | 7 | ifInErrors | 0 |
| 114 | interfaces | 7 | ifOutOctets | 0 |
| 115 | interfaces | 7 | ifOutDiscards | 0 |
| 116 | interfaces | 7 | ifOutErrors | 0 |
| 117 | interfaces | 7 | ifName | LAG-2 |
| 118 | interfaces | 7 | ifHCInOctets | 0 |
| 119 | interfaces | 7 | ifHCOutOctets | 0 |
| 120 | interfaces | 7 | ifHighSpeed | 0 |
| 121 | interfaces | 1003 | ifDescr | VLAN_MGMT |
| 122 | interfaces | 1003 | ifType | ethernetCsmacd |
| 123 | interfaces | 1003 | ifMtu | 2000 |
| 124 | interfaces | 1003 | ifSpeed | 0 |
| 125 | interfaces | 1003 | ifPhysAddress | 0:15:ad:47:3e:65 |
| 126 | interfaces | 1003 | ifAdminStatus | up |
| 127 | interfaces | 1003 | ifOperStatus | up |
| 128 | interfaces | 1003 | ifInOctets | 0 |
| 129 | interfaces | 1003 | ifInDiscards | 0 |
| 130 | interfaces | 1003 | ifInErrors | 0 |
| 131 | interfaces | 1003 | ifOutOctets | 0 |
| 132 | interfaces | 1003 | ifOutDiscards | 0 |
| 133 | interfaces | 1003 | ifOutErrors | 0 |
| 134 | interfaces | 1003 | ifName | VLAN_MGMT |
| 135 | interfaces | 1003 | ifHCInOctets | 0 |
| 136 | interfaces | 1003 | ifHCOutOctets | 0 |
| 137 | interfaces | 1003 | ifHighSpeed | 0 |
| 138 | interfaces | 15 | ifDescr | Virtual (15) |
| 139 | interfaces | 15 | ifName | Virtual (15) |
| 140 | interfaces | 15 | synthetic | 1 |
| 141 | interfaces | 10 | ifDescr | Virtual (10) |
| 142 | interfaces | 10 | ifName | Virtual (10) |
| 143 | interfaces | 10 | synthetic | 1 |
| 144 | connectors | 1 | id | 1 |
| 145 | connectors | 1 | name | SFP-1 |
| 146 | connectors | 1 | type | fiberLC |
| 147 | connectors | 1 | poeSupport | false |
| 148 | connectors | 2 | id | 2 |
| 149 | connectors | 2 | name | SFP-2 |
| 150 | connectors | 2 | type | fiberLC |
| 151 | connectors | 2 | poeSupport | false |
| 152 | connectors | 3 | id | 3 |
| 153 | connectors | 3 | name | SFP-3 |
| 154 | connectors | 3 | type | fiberLC |
| 155 | connectors | 3 | poeSupport | false |
| 156 | connectors | 4 | id | 4 |
| 157 | connectors | 4 | name | SFP-4 |
| 158 | connectors | 4 | type | fiberLC |
| 159 | connectors | 4 | poeSupport | false |
| 160 | connectors | 5 | id | 5 |
| 161 | connectors | 5 | name | Management |
| 162 | connectors | 5 | type | rj45 |
| 163 | connectors | 5 | poeSupport | false |
| 164 | power_supplies | 2 | id | 2 |
| 165 | power_supplies | 2 | name | Feed A |
| 166 | power_supplies | 2 | type | pwrminus48volts |
| 167 | power_supplies | 2 | present | true |
| 168 | power_supplies | 3 | id | 3 |
| 169 | power_supplies | 3 | name | Feed B |
| 170 | power_supplies | 3 | type | pwrminus48volts |
| 171 | power_supplies | 3 | present | false |
| 172 | temperature_sensors | 1 | currentTemp | 44 |
| 173 | temperature_sensors | 1 | highThreshold | 85 |
| 174 | temperature_sensors | 1 | highAlarmEnabled | false |
| 175 | temperature_sensors | 1 | criticalThreshold | 90 |
| 176 | temperature_sensors | 1 | criticalAlarmEnabled | false |
| 177 | temperature_sensors | 1 | label | Sensor 1 |
| 178 | temperature_sensors | 2 | currentTemp | 34 |
| 179 | temperature_sensors | 2 | highThreshold | 85 |
| 180 | temperature_sensors | 2 | highAlarmEnabled | false |
| 181 | temperature_sensors | 2 | criticalThreshold | 90 |
| 182 | temperature_sensors | 2 | criticalAlarmEnabled | false |
| 183 | temperature_sensors | 2 | label | Sensor 2 |
| 184 | sfp_info | 1 | connectorIdx | 1 |
| 185 | sfp_info | 1 | connectorType | sfpLC |
| 186 | sfp_info | 1 | vendor | OEM |
| 187 | sfp_info | 1 | vendorOui | ... |
| 188 | sfp_info | 1 | vendorPn | SFP-LX-SM....... |
| 189 | sfp_info | 1 | vendorRev | 1.0 ...NCI50L085 |
| 190 | sfp_info | 1 | wavelength | 1310 |
| 191 | sfp_info | 1 | serialNum | NCI50L0853 |
| 192 | sfp_info | 1 | mfgYear | 2009 |
| 193 | sfp_info | 1 | mfgMonth | 10 |
| 194 | sfp_info | 1 | mfgDay | 1 |
| 195 | sfp_info | 1 | lot | 0 |
| 196 | sfp_info | 1 | rev8472 | undefined |
| 197 | sfp_info | 1 | present | true |
| 198 | sfp_info | 1 | diagCapable | false |
| 199 | sfp_info | 1 | internalCal | false |
| 200 | sfp_info | 1 | alarmCapable | false |
| 201 | sfp_info | 1 | idType | 3 |
| 202 | sfp_info | 1 | extIdType | 4 |
| 203 | sfp_info | 1 | transCode | ...... |
| 204 | sfp_info | 3 | connectorIdx | 3 |
| 205 | sfp_info | 3 | connectorType | 128 |
| 206 | sfp_info | 3 | vendor | PROLABS |
| 207 | sfp_info | 3 | vendorOui | ... |
| 208 | sfp_info | 3 | vendorPn | SFP-1000BASE-T-C |
| 209 | sfp_info | 3 | vendorRev | A2 ...PRL940039 |
| 210 | sfp_info | 3 | wavelength | 0 |
| 211 | sfp_info | 3 | serialNum | PRL940039251 |
| 212 | sfp_info | 3 | mfgYear | 2021 |
| 213 | sfp_info | 3 | mfgMonth | 8 |
| 214 | sfp_info | 3 | mfgDay | 16 |
| 215 | sfp_info | 3 | lot | 0 |
| 216 | sfp_info | 3 | rev8472 | undefined |
| 217 | sfp_info | 3 | present | true |
| 218 | sfp_info | 3 | diagCapable | false |
| 219 | sfp_info | 3 | internalCal | false |
| 220 | sfp_info | 3 | alarmCapable | false |
| 221 | sfp_info | 3 | idType | 3 |
| 222 | sfp_info | 3 | extIdType | 4 |
| 223 | sfp_info | 3 | transCode | ........ |
| 224 | sfp_diagnostics | 1 | connectorIdx | 1 |
| 225 | sfp_diagnostics | 1 | temperature | 0 |
| 226 | sfp_diagnostics | 1 | supplyVoltage | 0 |
| 227 | sfp_diagnostics | 1 | laserBiasCurrent | 0 |
| 228 | sfp_diagnostics | 1 | txPower_uW | 0 |
| 229 | sfp_diagnostics | 1 | rxPower_uW | 0 |
| 230 | sfp_diagnostics | 1 | txPower_dBm | -inf dBm |
| 231 | sfp_diagnostics | 1 | rxPower_dBm | -inf dBm |
| 232 | sfp_diagnostics | 3 | connectorIdx | 3 |
| 233 | sfp_diagnostics | 3 | temperature | 0 |
| 234 | sfp_diagnostics | 3 | supplyVoltage | 0 |
| 235 | sfp_diagnostics | 3 | laserBiasCurrent | 0 |
| 236 | sfp_diagnostics | 3 | txPower_uW | 0 |
| 237 | sfp_diagnostics | 3 | rxPower_uW | 0 |
| 238 | sfp_diagnostics | 3 | txPower_dBm | -inf dBm |
| 239 | sfp_diagnostics | 3 | rxPower_dBm | -inf dBm |
| 240 | sfp_thresholds | 1 | connectorIdx | 1 |
| 241 | sfp_thresholds | 1 | tempHighAlarm | 0 |
| 242 | sfp_thresholds | 1 | tempLowAlarm | 0 |
| 243 | sfp_thresholds | 1 | tempHighWarn | 0 |
| 244 | sfp_thresholds | 1 | tempLowWarn | 0 |
| 245 | sfp_thresholds | 1 | vccHighAlarm | 0 |
| 246 | sfp_thresholds | 1 | vccLowAlarm | 0 |
| 247 | sfp_thresholds | 1 | vccHighWarn | 0 |
| 248 | sfp_thresholds | 1 | vccLowWarn | 0 |
| 249 | sfp_thresholds | 1 | lbcHighAlarm | 0 |
| 250 | sfp_thresholds | 1 | lbcLowAlarm | 0 |
| 251 | sfp_thresholds | 1 | lbcHighWarn | 0 |
| 252 | sfp_thresholds | 1 | lbcLowWarn | 0 |
| 253 | sfp_thresholds | 1 | txPwrHighAlarm | 0 |
| 254 | sfp_thresholds | 1 | txPwrLowAlarm | 0 |
| 255 | sfp_thresholds | 1 | txPwrHighWarn | 0 |
| 256 | sfp_thresholds | 1 | txPwrLowWarn | 0 |
| 257 | sfp_thresholds | 1 | rxPwrHighAlarm | 0 |
| 258 | sfp_thresholds | 1 | rxPwrLowAlarm | 0 |
| 259 | sfp_thresholds | 1 | rxPwrHighWarn | 0 |
| 260 | sfp_thresholds | 1 | rxPwrLowWarn | 0 |
| 261 | sfp_thresholds | 1 | txPwrHighAlarm_dBm | -in. dBm |
| 262 | sfp_thresholds | 1 | txPwrLowAlarm_dBm | -in. dBm |
| 263 | sfp_thresholds | 1 | txPwrHighWarn_dBm | -in. dBm |
| 264 | sfp_thresholds | 1 | txPwrLowWarn_dBm | -in. dBm |
| 265 | sfp_thresholds | 1 | rxPwrHighAlarm_dBm | -in. dBm |
| 266 | sfp_thresholds | 1 | rxPwrLowAlarm_dBm | -in. dBm |
| 267 | sfp_thresholds | 1 | rxPwrHighWarn_dBm | -in. dBm |
| 268 | sfp_thresholds | 1 | rxPwrLowWarn_dBm | -in. dBm |
| 269 | sfp_thresholds | 3 | connectorIdx | 3 |
| 270 | sfp_thresholds | 3 | tempHighAlarm | 0 |
| 271 | sfp_thresholds | 3 | tempLowAlarm | 0 |
| 272 | sfp_thresholds | 3 | tempHighWarn | 0 |
| 273 | sfp_thresholds | 3 | tempLowWarn | 0 |
| 274 | sfp_thresholds | 3 | vccHighAlarm | 0 |
| 275 | sfp_thresholds | 3 | vccLowAlarm | 0 |
| 276 | sfp_thresholds | 3 | vccHighWarn | 0 |
| 277 | sfp_thresholds | 3 | vccLowWarn | 0 |
| 278 | sfp_thresholds | 3 | lbcHighAlarm | 0 |
| 279 | sfp_thresholds | 3 | lbcLowAlarm | 0 |
| 280 | sfp_thresholds | 3 | lbcHighWarn | 0 |
| 281 | sfp_thresholds | 3 | lbcLowWarn | 0 |
| 282 | sfp_thresholds | 3 | txPwrHighAlarm | 0 |
| 283 | sfp_thresholds | 3 | txPwrLowAlarm | 0 |
| 284 | sfp_thresholds | 3 | txPwrHighWarn | 0 |
| 285 | sfp_thresholds | 3 | txPwrLowWarn | 0 |
| 286 | sfp_thresholds | 3 | rxPwrHighAlarm | 0 |
| 287 | sfp_thresholds | 3 | rxPwrLowAlarm | 0 |
| 288 | sfp_thresholds | 3 | rxPwrHighWarn | 0 |
| 289 | sfp_thresholds | 3 | rxPwrLowWarn | 0 |
| 290 | sfp_thresholds | 3 | txPwrHighAlarm_dBm | -in. dBm |
| 291 | sfp_thresholds | 3 | txPwrLowAlarm_dBm | -in. dBm |
| 292 | sfp_thresholds | 3 | txPwrHighWarn_dBm | -in. dBm |
| 293 | sfp_thresholds | 3 | txPwrLowWarn_dBm | -in. dBm |
| 294 | sfp_thresholds | 3 | rxPwrHighAlarm_dBm | -in. dBm |
| 295 | sfp_thresholds | 3 | rxPwrLowAlarm_dBm | -in. dBm |
| 296 | sfp_thresholds | 3 | rxPwrHighWarn_dBm | -in. dBm |
| 297 | sfp_thresholds | 3 | rxPwrLowWarn_dBm | -in. dBm |
| 298 | alarm_config | 1 | id | 1 |
| 299 | alarm_config | 1 | number | 8000001 |
| 300 | alarm_config | 1 | description | First overheat threshold |
| 301 | alarm_config | 1 | enabled | true |
| 302 | alarm_config | 1 | severity | major |
| 303 | alarm_config | 1 | serviceAffecting | false |
| 304 | alarm_config | 1 | extNumber | 8.0000.01 |
| 305 | alarm_config | 1 | conditionType | TEMP-HIGH-WN |
| 306 | alarm_config | 1 | amoType | ENV.TEMP |
| 307 | alarm_config | 1 | on | 0 |
| 308 | alarm_config | 2 | id | 2 |
| 309 | alarm_config | 2 | number | 8000002 |
| 310 | alarm_config | 2 | description | Second overheat threshold |
| 311 | alarm_config | 2 | enabled | true |
| 312 | alarm_config | 2 | severity | critical |
| 313 | alarm_config | 2 | serviceAffecting | false |
| 314 | alarm_config | 2 | extNumber | 8.0000.02 |
| 315 | alarm_config | 2 | conditionType | TEMP-HIGH-ALM |
| 316 | alarm_config | 2 | amoType | ENV.TEMP |
| 317 | alarm_config | 2 | on | 0 |
| 318 | alarm_config | 3 | id | 3 |
| 319 | alarm_config | 3 | number | 8000004 |
| 320 | alarm_config | 3 | description | No power supply on feed A |
| 321 | alarm_config | 3 | enabled | true |
| 322 | alarm_config | 3 | severity | major |
| 323 | alarm_config | 3 | serviceAffecting | false |
| 324 | alarm_config | 3 | extNumber | 8.0000.04 |
| 325 | alarm_config | 3 | conditionType | PWR-LOSS |
| 326 | alarm_config | 3 | amoType | ENV.PWR-FEEDA |
| 327 | alarm_config | 3 | on | 0 |
| 328 | alarm_config | 4 | id | 4 |
| 329 | alarm_config | 4 | number | 8000005 |
| 330 | alarm_config | 4 | description | No power supply on feed B |
| 331 | alarm_config | 4 | enabled | true |
| 332 | alarm_config | 4 | severity | major |
| 333 | alarm_config | 4 | serviceAffecting | false |
| 334 | alarm_config | 4 | extNumber | 8.0000.05 |
| 335 | alarm_config | 4 | conditionType | PWR-LOSS |
| 336 | alarm_config | 4 | amoType | ENV.PWR-FEEDB |
| 337 | alarm_config | 4 | on | 0 |
| 338 | alarm_config | 5 | id | 5 |
| 339 | alarm_config | 5 | number | 8000101 |
| 340 | alarm_config | 5 | description | First overheat threshold |
| 341 | alarm_config | 5 | enabled | true |
| 342 | alarm_config | 5 | severity | major |
| 343 | alarm_config | 5 | serviceAffecting | false |
| 344 | alarm_config | 5 | extNumber | 8.0001.01 |
| 345 | alarm_config | 5 | conditionType | TEMP-HIGH-WN |
| 346 | alarm_config | 5 | amoType | ENV.TEMP |
| 347 | alarm_config | 5 | on | 0 |
| 348 | alarm_config | 6 | id | 6 |
| 349 | alarm_config | 6 | number | 8000102 |
| 350 | alarm_config | 6 | description | Second overheat threshold |
| 351 | alarm_config | 6 | enabled | true |
| 352 | alarm_config | 6 | severity | critical |
| 353 | alarm_config | 6 | serviceAffecting | false |
| 354 | alarm_config | 6 | extNumber | 8.0001.02 |
| 355 | alarm_config | 6 | conditionType | TEMP-HIGH-ALM |
| 356 | alarm_config | 6 | amoType | ENV.TEMP |
| 357 | alarm_config | 6 | on | 0 |
| 358 | alarm_config | 7 | id | 7 |
| 359 | alarm_config | 7 | number | 8000040 |
| 360 | alarm_config | 7 | description | Fan 1 slow |
| 361 | alarm_config | 7 | enabled | true |
| 362 | alarm_config | 7 | severity | major |
| 363 | alarm_config | 7 | serviceAffecting | false |
| 364 | alarm_config | 7 | extNumber | 8.0000.40 |
| 365 | alarm_config | 7 | conditionType | FAN-SLOW |
| 366 | alarm_config | 7 | amoType | ENV.FAN-SLOW |
| 367 | alarm_config | 7 | on | 0 |
| 368 | alarm_config | 8 | id | 8 |
| 369 | alarm_config | 8 | number | 8000041 |
| 370 | alarm_config | 8 | description | Fan 1 failure |
| 371 | alarm_config | 8 | enabled | true |
| 372 | alarm_config | 8 | severity | critical |
| 373 | alarm_config | 8 | serviceAffecting | false |
| 374 | alarm_config | 8 | extNumber | 8.0000.41 |
| 375 | alarm_config | 8 | conditionType | FAN-FAILURE |
| 376 | alarm_config | 8 | amoType | ENV.FAN-FAILURE |
| 377 | alarm_config | 8 | on | 0 |
| 378 | alarm_config | 9 | id | 9 |
| 379 | alarm_config | 9 | number | 8000140 |
| 380 | alarm_config | 9 | description | Fan 2 slow |
| 381 | alarm_config | 9 | enabled | true |
| 382 | alarm_config | 9 | severity | major |
| 383 | alarm_config | 9 | serviceAffecting | false |
| 384 | alarm_config | 9 | extNumber | 8.0001.40 |
| 385 | alarm_config | 9 | conditionType | FAN-SLOW |
| 386 | alarm_config | 9 | amoType | ENV.FAN-SLOW |
| 387 | alarm_config | 9 | on | 0 |
| 388 | alarm_config | 10 | id | 10 |
| 389 | alarm_config | 10 | number | 8000141 |
| 390 | alarm_config | 10 | description | Fan 2 failure |
| 391 | alarm_config | 10 | enabled | true |
| 392 | alarm_config | 10 | severity | critical |
| 393 | alarm_config | 10 | serviceAffecting | false |
| 394 | alarm_config | 10 | extNumber | 8.0001.41 |
| 395 | alarm_config | 10 | conditionType | FAN-FAILURE |
| 396 | alarm_config | 10 | amoType | ENV.FAN-FAILURE |
| 397 | alarm_config | 10 | on | 0 |
| 398 | alarm_config | 11 | id | 11 |
| 399 | alarm_config | 11 | number | 2000101 |
| 400 | alarm_config | 11 | description | SFP-1 temperature high alarm |
| 401 | alarm_config | 11 | enabled | true |
| 402 | alarm_config | 11 | severity | major |
| 403 | alarm_config | 11 | serviceAffecting | false |
| 404 | alarm_config | 11 | extNumber | 2.0001.01 |
| 405 | alarm_config | 11 | conditionType | TEMP-HIGH-ALM |
| 406 | alarm_config | 11 | amoType | SFP.1 |
| 407 | alarm_config | 11 | on | 0 |
| 408 | alarm_config | 12 | id | 12 |
| 409 | alarm_config | 12 | number | 2000102 |
| 410 | alarm_config | 12 | description | SFP-1 temperature low alarm |
| 411 | alarm_config | 12 | enabled | true |
| 412 | alarm_config | 12 | severity | major |
| 413 | alarm_config | 12 | serviceAffecting | false |
| 414 | alarm_config | 12 | extNumber | 2.0001.02 |
| 415 | alarm_config | 12 | conditionType | TEMP-LOW-ALM |
| 416 | alarm_config | 12 | amoType | SFP.1 |
| 417 | alarm_config | 12 | on | 0 |
| 418 | alarm_config | 13 | id | 13 |
| 419 | alarm_config | 13 | number | 2000103 |
| 420 | alarm_config | 13 | description | SFP-1 temperature high warning |
| 421 | alarm_config | 13 | enabled | true |
| 422 | alarm_config | 13 | severity | info |
| 423 | alarm_config | 13 | serviceAffecting | false |
| 424 | alarm_config | 13 | extNumber | 2.0001.03 |
| 425 | alarm_config | 13 | conditionType | TEMP-HIGH-WN |
| 426 | alarm_config | 13 | amoType | SFP.1 |
| 427 | alarm_config | 13 | on | 0 |
| 428 | alarm_config | 14 | id | 14 |
| 429 | alarm_config | 14 | number | 2000104 |
| 430 | alarm_config | 14 | description | SFP-1 temperature low warning |
| 431 | alarm_config | 14 | enabled | true |
| 432 | alarm_config | 14 | severity | info |
| 433 | alarm_config | 14 | serviceAffecting | false |
| 434 | alarm_config | 14 | extNumber | 2.0001.04 |
| 435 | alarm_config | 14 | conditionType | TEMP-LOW-WN |
| 436 | alarm_config | 14 | amoType | SFP.1 |
| 437 | alarm_config | 14 | on | 0 |
| 438 | alarm_config | 15 | id | 15 |
| 439 | alarm_config | 15 | number | 2000105 |
| 440 | alarm_config | 15 | description | SFP-1 supply voltage high alarm |
| 441 | alarm_config | 15 | enabled | true |
| 442 | alarm_config | 15 | severity | major |
| 443 | alarm_config | 15 | serviceAffecting | false |
| 444 | alarm_config | 15 | extNumber | 2.0001.05 |
| 445 | alarm_config | 15 | conditionType | VCC-HIGH-ALM |
| 446 | alarm_config | 15 | amoType | SFP.1 |
| 447 | alarm_config | 15 | on | 0 |
| 448 | alarm_config | 16 | id | 16 |
| 449 | alarm_config | 16 | number | 2000106 |
| 450 | alarm_config | 16 | description | SFP-1 supply voltage low alarm |
| 451 | alarm_config | 16 | enabled | true |
| 452 | alarm_config | 16 | severity | major |
| 453 | alarm_config | 16 | serviceAffecting | false |
| 454 | alarm_config | 16 | extNumber | 2.0001.06 |
| 455 | alarm_config | 16 | conditionType | VCC-LOW-ALM |
| 456 | alarm_config | 16 | amoType | SFP.1 |
| 457 | alarm_config | 16 | on | 0 |
| 458 | alarm_config | 17 | id | 17 |
| 459 | alarm_config | 17 | number | 2000107 |
| 460 | alarm_config | 17 | description | SFP-1 supply voltage high warning |
| 461 | alarm_config | 17 | enabled | true |
| 462 | alarm_config | 17 | severity | info |
| 463 | alarm_config | 17 | serviceAffecting | false |
| 464 | alarm_config | 17 | extNumber | 2.0001.07 |
| 465 | alarm_config | 17 | conditionType | VCC-HIGH-WN |
| 466 | alarm_config | 17 | amoType | SFP.1 |
| 467 | alarm_config | 17 | on | 0 |
| 468 | alarm_config | 18 | id | 18 |
| 469 | alarm_config | 18 | number | 2000108 |
| 470 | alarm_config | 18 | description | SFP-1 supply voltage low warning |
| 471 | alarm_config | 18 | enabled | true |
| 472 | alarm_config | 18 | severity | info |
| 473 | alarm_config | 18 | serviceAffecting | false |
| 474 | alarm_config | 18 | extNumber | 2.0001.08 |
| 475 | alarm_config | 18 | conditionType | VCC-LOW-WN |
| 476 | alarm_config | 18 | amoType | SFP.1 |
| 477 | alarm_config | 18 | on | 0 |
| 478 | alarm_config | 19 | id | 19 |
| 479 | alarm_config | 19 | number | 2000109 |
| 480 | alarm_config | 19 | description | SFP-1 laser bias current high alarm |
| 481 | alarm_config | 19 | enabled | true |
| 482 | alarm_config | 19 | severity | major |
| 483 | alarm_config | 19 | serviceAffecting | false |
| 484 | alarm_config | 19 | extNumber | 2.0001.09 |
| 485 | alarm_config | 19 | conditionType | LBC-HIGH-ALM |
| 486 | alarm_config | 19 | amoType | SFP.1 |
| 487 | alarm_config | 19 | on | 0 |
| 488 | alarm_config | 20 | id | 20 |
| 489 | alarm_config | 20 | number | 2000110 |
| 490 | alarm_config | 20 | description | SFP-1 laser bias current low alarm |
| 491 | alarm_config | 20 | enabled | true |
| 492 | alarm_config | 20 | severity | major |
| 493 | alarm_config | 20 | serviceAffecting | false |
| 494 | alarm_config | 20 | extNumber | 2.0001.10 |
| 495 | alarm_config | 20 | conditionType | LBC-LOW-ALM |
| 496 | alarm_config | 20 | amoType | SFP.1 |
| 497 | alarm_config | 20 | on | 0 |
| 498 | alarm_config | 21 | id | 21 |
| 499 | alarm_config | 21 | number | 2000111 |
| 500 | alarm_config | 21 | description | SFP-1 laser bias current high warning |
| 501 | alarm_config | 21 | enabled | true |
| 502 | alarm_config | 21 | severity | info |
| 503 | alarm_config | 21 | serviceAffecting | false |
| 504 | alarm_config | 21 | extNumber | 2.0001.11 |
| 505 | alarm_config | 21 | conditionType | LBC-HIGH-WN |
| 506 | alarm_config | 21 | amoType | SFP.1 |
| 507 | alarm_config | 21 | on | 0 |
| 508 | alarm_config | 22 | id | 22 |
| 509 | alarm_config | 22 | number | 2000112 |
| 510 | alarm_config | 22 | description | SFP-1 laser bias current low warning |
| 511 | alarm_config | 22 | enabled | true |
| 512 | alarm_config | 22 | severity | info |
| 513 | alarm_config | 22 | serviceAffecting | false |
| 514 | alarm_config | 22 | extNumber | 2.0001.12 |
| 515 | alarm_config | 22 | conditionType | LBC-LOW-WN |
| 516 | alarm_config | 22 | amoType | SFP.1 |
| 517 | alarm_config | 22 | on | 0 |
| 518 | alarm_config | 23 | id | 23 |
| 519 | alarm_config | 23 | number | 2000113 |
| 520 | alarm_config | 23 | description | SFP-1 transmit power high alarm |
| 521 | alarm_config | 23 | enabled | true |
| 522 | alarm_config | 23 | severity | major |
| 523 | alarm_config | 23 | serviceAffecting | false |
| 524 | alarm_config | 23 | extNumber | 2.0001.13 |
| 525 | alarm_config | 23 | conditionType | TX-PWR-HIGH-ALM |
| 526 | alarm_config | 23 | amoType | SFP.1 |
| 527 | alarm_config | 23 | on | 0 |
| 528 | alarm_config | 24 | id | 24 |
| 529 | alarm_config | 24 | number | 2000114 |
| 530 | alarm_config | 24 | description | SFP-1 transmit power low alarm |
| 531 | alarm_config | 24 | enabled | true |
| 532 | alarm_config | 24 | severity | major |
| 533 | alarm_config | 24 | serviceAffecting | false |
| 534 | alarm_config | 24 | extNumber | 2.0001.14 |
| 535 | alarm_config | 24 | conditionType | TX-PWR-LOW-ALM |
| 536 | alarm_config | 24 | amoType | SFP.1 |
| 537 | alarm_config | 24 | on | 0 |
| 538 | alarm_config | 25 | id | 25 |
| 539 | alarm_config | 25 | number | 2000115 |
| 540 | alarm_config | 25 | description | SFP-1 transmit power high warning |
| 541 | alarm_config | 25 | enabled | true |
| 542 | alarm_config | 25 | severity | info |
| 543 | alarm_config | 25 | serviceAffecting | false |
| 544 | alarm_config | 25 | extNumber | 2.0001.15 |
| 545 | alarm_config | 25 | conditionType | TX-PWR-HIGH-WN |
| 546 | alarm_config | 25 | amoType | SFP.1 |
| 547 | alarm_config | 25 | on | 0 |
| 548 | alarm_config | 26 | id | 26 |
| 549 | alarm_config | 26 | number | 2000116 |
| 550 | alarm_config | 26 | description | SFP-1 transmit power low warning |
| 551 | alarm_config | 26 | enabled | true |
| 552 | alarm_config | 26 | severity | info |
| 553 | alarm_config | 26 | serviceAffecting | false |
| 554 | alarm_config | 26 | extNumber | 2.0001.16 |
| 555 | alarm_config | 26 | conditionType | TX-PWR-LOW-WN |
| 556 | alarm_config | 26 | amoType | SFP.1 |
| 557 | alarm_config | 26 | on | 0 |
| 558 | alarm_config | 27 | id | 27 |
| 559 | alarm_config | 27 | number | 2000117 |
| 560 | alarm_config | 27 | description | SFP-1 receive power high alarm |
| 561 | alarm_config | 27 | enabled | true |
| 562 | alarm_config | 27 | severity | major |
| 563 | alarm_config | 27 | serviceAffecting | false |
| 564 | alarm_config | 27 | extNumber | 2.0001.17 |
| 565 | alarm_config | 27 | conditionType | RX-PWR-HIGH-ALM |
| 566 | alarm_config | 27 | amoType | SFP.1 |
| 567 | alarm_config | 27 | on | 0 |
| 568 | alarm_config | 28 | id | 28 |
| 569 | alarm_config | 28 | number | 2000118 |
| 570 | alarm_config | 28 | description | SFP-1 receive power low alarm |
| 571 | alarm_config | 28 | enabled | true |
| 572 | alarm_config | 28 | severity | major |
| 573 | alarm_config | 28 | serviceAffecting | false |
| 574 | alarm_config | 28 | extNumber | 2.0001.18 |
| 575 | alarm_config | 28 | conditionType | RX-PWR-LOW-ALM |
| 576 | alarm_config | 28 | amoType | SFP.1 |
| 577 | alarm_config | 28 | on | 0 |
| 578 | alarm_config | 29 | id | 29 |
| 579 | alarm_config | 29 | number | 2000119 |
| 580 | alarm_config | 29 | description | SFP-1 receive power high warning |
| 581 | alarm_config | 29 | enabled | true |
| 582 | alarm_config | 29 | severity | info |
| 583 | alarm_config | 29 | serviceAffecting | false |
| 584 | alarm_config | 29 | extNumber | 2.0001.19 |
| 585 | alarm_config | 29 | conditionType | RX-PWR-HIGH-WN |
| 586 | alarm_config | 29 | amoType | SFP.1 |
| 587 | alarm_config | 29 | on | 0 |
| 588 | alarm_config | 30 | id | 30 |
| 589 | alarm_config | 30 | number | 2000120 |
| 590 | alarm_config | 30 | description | SFP-1 receive power low warning |
| 591 | alarm_config | 30 | enabled | true |
| 592 | alarm_config | 30 | severity | info |
| 593 | alarm_config | 30 | serviceAffecting | false |
| 594 | alarm_config | 30 | extNumber | 2.0001.20 |
| 595 | alarm_config | 30 | conditionType | RX-PWR-LOW-WN |
| 596 | alarm_config | 30 | amoType | SFP.1 |
| 597 | alarm_config | 30 | on | 0 |
| 598 | alarm_config | 31 | id | 31 |
| 599 | alarm_config | 31 | number | 2000121 |
| 600 | alarm_config | 31 | description | SFP-1 not present |
| 601 | alarm_config | 31 | enabled | true |
| 602 | alarm_config | 31 | severity | major |
| 603 | alarm_config | 31 | serviceAffecting | false |
| 604 | alarm_config | 31 | extNumber | 2.0001.21 |
| 605 | alarm_config | 31 | conditionType | MOD-NOT-PRESENT |
| 606 | alarm_config | 31 | amoType | SFP.1 |
| 607 | alarm_config | 31 | on | 0 |
| 608 | alarm_config | 32 | id | 32 |
| 609 | alarm_config | 32 | number | 2000201 |
| 610 | alarm_config | 32 | description | SFP-2 temperature high alarm |
| 611 | alarm_config | 32 | enabled | true |
| 612 | alarm_config | 32 | severity | major |
| 613 | alarm_config | 32 | serviceAffecting | false |
| 614 | alarm_config | 32 | extNumber | 2.0002.01 |
| 615 | alarm_config | 32 | conditionType | TEMP-HIGH-ALM |
| 616 | alarm_config | 32 | amoType | SFP.2 |
| 617 | alarm_config | 32 | on | 0 |
| 618 | alarm_config | 33 | id | 33 |
| 619 | alarm_config | 33 | number | 2000202 |
| 620 | alarm_config | 33 | description | SFP-2 temperature low alarm |
| 621 | alarm_config | 33 | enabled | true |
| 622 | alarm_config | 33 | severity | major |
| 623 | alarm_config | 33 | serviceAffecting | false |
| 624 | alarm_config | 33 | extNumber | 2.0002.02 |
| 625 | alarm_config | 33 | conditionType | TEMP-LOW-ALM |
| 626 | alarm_config | 33 | amoType | SFP.2 |
| 627 | alarm_config | 33 | on | 0 |
| 628 | alarm_config | 34 | id | 34 |
| 629 | alarm_config | 34 | number | 2000203 |
| 630 | alarm_config | 34 | description | SFP-2 temperature high warning |
| 631 | alarm_config | 34 | enabled | true |
| 632 | alarm_config | 34 | severity | info |
| 633 | alarm_config | 34 | serviceAffecting | false |
| 634 | alarm_config | 34 | extNumber | 2.0002.03 |
| 635 | alarm_config | 34 | conditionType | TEMP-HIGH-WN |
| 636 | alarm_config | 34 | amoType | SFP.2 |
| 637 | alarm_config | 34 | on | 0 |
| 638 | alarm_config | 35 | id | 35 |
| 639 | alarm_config | 35 | number | 2000204 |
| 640 | alarm_config | 35 | description | SFP-2 temperature low warning |
| 641 | alarm_config | 35 | enabled | true |
| 642 | alarm_config | 35 | severity | info |
| 643 | alarm_config | 35 | serviceAffecting | false |
| 644 | alarm_config | 35 | extNumber | 2.0002.04 |
| 645 | alarm_config | 35 | conditionType | TEMP-LOW-WN |
| 646 | alarm_config | 35 | amoType | SFP.2 |
| 647 | alarm_config | 35 | on | 0 |
| 648 | alarm_config | 36 | id | 36 |
| 649 | alarm_config | 36 | number | 2000205 |
| 650 | alarm_config | 36 | description | SFP-2 supply voltage high alarm |
| 651 | alarm_config | 36 | enabled | true |
| 652 | alarm_config | 36 | severity | major |
| 653 | alarm_config | 36 | serviceAffecting | false |
| 654 | alarm_config | 36 | extNumber | 2.0002.05 |
| 655 | alarm_config | 36 | conditionType | VCC-HIGH-ALM |
| 656 | alarm_config | 36 | amoType | SFP.2 |
| 657 | alarm_config | 36 | on | 0 |
| 658 | alarm_config | 37 | id | 37 |
| 659 | alarm_config | 37 | number | 2000206 |
| 660 | alarm_config | 37 | description | SFP-2 supply voltage low alarm |
| 661 | alarm_config | 37 | enabled | true |
| 662 | alarm_config | 37 | severity | major |
| 663 | alarm_config | 37 | serviceAffecting | false |
| 664 | alarm_config | 37 | extNumber | 2.0002.06 |
| 665 | alarm_config | 37 | conditionType | VCC-LOW-ALM |
| 666 | alarm_config | 37 | amoType | SFP.2 |
| 667 | alarm_config | 37 | on | 0 |
| 668 | alarm_config | 38 | id | 38 |
| 669 | alarm_config | 38 | number | 2000207 |
| 670 | alarm_config | 38 | description | SFP-2 supply voltage high warning |
| 671 | alarm_config | 38 | enabled | true |
| 672 | alarm_config | 38 | severity | info |
| 673 | alarm_config | 38 | serviceAffecting | false |
| 674 | alarm_config | 38 | extNumber | 2.0002.07 |
| 675 | alarm_config | 38 | conditionType | VCC-HIGH-WN |
| 676 | alarm_config | 38 | amoType | SFP.2 |
| 677 | alarm_config | 38 | on | 0 |
| 678 | alarm_config | 39 | id | 39 |
| 679 | alarm_config | 39 | number | 2000208 |
| 680 | alarm_config | 39 | description | SFP-2 supply voltage low warning |
| 681 | alarm_config | 39 | enabled | true |
| 682 | alarm_config | 39 | severity | info |
| 683 | alarm_config | 39 | serviceAffecting | false |
| 684 | alarm_config | 39 | extNumber | 2.0002.08 |
| 685 | alarm_config | 39 | conditionType | VCC-LOW-WN |
| 686 | alarm_config | 39 | amoType | SFP.2 |
| 687 | alarm_config | 39 | on | 0 |
| 688 | alarm_config | 40 | id | 40 |
| 689 | alarm_config | 40 | number | 2000209 |
| 690 | alarm_config | 40 | description | SFP-2 laser bias current high alarm |
| 691 | alarm_config | 40 | enabled | true |
| 692 | alarm_config | 40 | severity | major |
| 693 | alarm_config | 40 | serviceAffecting | false |
| 694 | alarm_config | 40 | extNumber | 2.0002.09 |
| 695 | alarm_config | 40 | conditionType | LBC-HIGH-ALM |
| 696 | alarm_config | 40 | amoType | SFP.2 |
| 697 | alarm_config | 40 | on | 0 |
| 698 | alarm_config | 41 | id | 41 |
| 699 | alarm_config | 41 | number | 2000210 |
| 700 | alarm_config | 41 | description | SFP-2 laser bias current low alarm |
| 701 | alarm_config | 41 | enabled | true |
| 702 | alarm_config | 41 | severity | major |
| 703 | alarm_config | 41 | serviceAffecting | false |
| 704 | alarm_config | 41 | extNumber | 2.0002.10 |
| 705 | alarm_config | 41 | conditionType | LBC-LOW-ALM |
| 706 | alarm_config | 41 | amoType | SFP.2 |
| 707 | alarm_config | 41 | on | 0 |
| 708 | alarm_config | 42 | id | 42 |
| 709 | alarm_config | 42 | number | 2000211 |
| 710 | alarm_config | 42 | description | SFP-2 laser bias current high warning |
| 711 | alarm_config | 42 | enabled | true |
| 712 | alarm_config | 42 | severity | info |
| 713 | alarm_config | 42 | serviceAffecting | false |
| 714 | alarm_config | 42 | extNumber | 2.0002.11 |
| 715 | alarm_config | 42 | conditionType | LBC-HIGH-WN |
| 716 | alarm_config | 42 | amoType | SFP.2 |
| 717 | alarm_config | 42 | on | 0 |
| 718 | alarm_config | 43 | id | 43 |
| 719 | alarm_config | 43 | number | 2000212 |
| 720 | alarm_config | 43 | description | SFP-2 laser bias current low warning |
| 721 | alarm_config | 43 | enabled | true |
| 722 | alarm_config | 43 | severity | info |
| 723 | alarm_config | 43 | serviceAffecting | false |
| 724 | alarm_config | 43 | extNumber | 2.0002.12 |
| 725 | alarm_config | 43 | conditionType | LBC-LOW-WN |
| 726 | alarm_config | 43 | amoType | SFP.2 |
| 727 | alarm_config | 43 | on | 0 |
| 728 | alarm_config | 44 | id | 44 |
| 729 | alarm_config | 44 | number | 2000213 |
| 730 | alarm_config | 44 | description | SFP-2 transmit power high alarm |
| 731 | alarm_config | 44 | enabled | true |
| 732 | alarm_config | 44 | severity | major |
| 733 | alarm_config | 44 | serviceAffecting | false |
| 734 | alarm_config | 44 | extNumber | 2.0002.13 |
| 735 | alarm_config | 44 | conditionType | TX-PWR-HIGH-ALM |
| 736 | alarm_config | 44 | amoType | SFP.2 |
| 737 | alarm_config | 44 | on | 0 |
| 738 | alarm_config | 45 | id | 45 |
| 739 | alarm_config | 45 | number | 2000214 |
| 740 | alarm_config | 45 | description | SFP-2 transmit power low alarm |
| 741 | alarm_config | 45 | enabled | true |
| 742 | alarm_config | 45 | severity | major |
| 743 | alarm_config | 45 | serviceAffecting | false |
| 744 | alarm_config | 45 | extNumber | 2.0002.14 |
| 745 | alarm_config | 45 | conditionType | TX-PWR-LOW-ALM |
| 746 | alarm_config | 45 | amoType | SFP.2 |
| 747 | alarm_config | 45 | on | 0 |
| 748 | alarm_config | 46 | id | 46 |
| 749 | alarm_config | 46 | number | 2000215 |
| 750 | alarm_config | 46 | description | SFP-2 transmit power high warning |
| 751 | alarm_config | 46 | enabled | true |
| 752 | alarm_config | 46 | severity | info |
| 753 | alarm_config | 46 | serviceAffecting | false |
| 754 | alarm_config | 46 | extNumber | 2.0002.15 |
| 755 | alarm_config | 46 | conditionType | TX-PWR-HIGH-WN |
| 756 | alarm_config | 46 | amoType | SFP.2 |
| 757 | alarm_config | 46 | on | 0 |
| 758 | alarm_config | 47 | id | 47 |
| 759 | alarm_config | 47 | number | 2000216 |
| 760 | alarm_config | 47 | description | SFP-2 transmit power low warning |
| 761 | alarm_config | 47 | enabled | true |
| 762 | alarm_config | 47 | severity | info |
| 763 | alarm_config | 47 | serviceAffecting | false |
| 764 | alarm_config | 47 | extNumber | 2.0002.16 |
| 765 | alarm_config | 47 | conditionType | TX-PWR-LOW-WN |
| 766 | alarm_config | 47 | amoType | SFP.2 |
| 767 | alarm_config | 47 | on | 0 |
| 768 | alarm_config | 48 | id | 48 |
| 769 | alarm_config | 48 | number | 2000217 |
| 770 | alarm_config | 48 | description | SFP-2 receive power high alarm |
| 771 | alarm_config | 48 | enabled | true |
| 772 | alarm_config | 48 | severity | major |
| 773 | alarm_config | 48 | serviceAffecting | false |
| 774 | alarm_config | 48 | extNumber | 2.0002.17 |
| 775 | alarm_config | 48 | conditionType | RX-PWR-HIGH-ALM |
| 776 | alarm_config | 48 | amoType | SFP.2 |
| 777 | alarm_config | 48 | on | 0 |
| 778 | alarm_config | 49 | id | 49 |
| 779 | alarm_config | 49 | number | 2000218 |
| 780 | alarm_config | 49 | description | SFP-2 receive power low alarm |
| 781 | alarm_config | 49 | enabled | true |
| 782 | alarm_config | 49 | severity | major |
| 783 | alarm_config | 49 | serviceAffecting | false |
| 784 | alarm_config | 49 | extNumber | 2.0002.18 |
| 785 | alarm_config | 49 | conditionType | RX-PWR-LOW-ALM |
| 786 | alarm_config | 49 | amoType | SFP.2 |
| 787 | alarm_config | 49 | on | 0 |
| 788 | alarm_config | 50 | id | 50 |
| 789 | alarm_config | 50 | number | 2000219 |
| 790 | alarm_config | 50 | description | SFP-2 receive power high warning |
| 791 | alarm_config | 50 | enabled | true |
| 792 | alarm_config | 50 | severity | info |
| 793 | alarm_config | 50 | serviceAffecting | false |
| 794 | alarm_config | 50 | extNumber | 2.0002.19 |
| 795 | alarm_config | 50 | conditionType | RX-PWR-HIGH-WN |
| 796 | alarm_config | 50 | amoType | SFP.2 |
| 797 | alarm_config | 50 | on | 0 |
| 798 | alarm_config | 51 | id | 51 |
| 799 | alarm_config | 51 | number | 2000220 |
| 800 | alarm_config | 51 | description | SFP-2 receive power low warning |
| 801 | alarm_config | 51 | enabled | true |
| 802 | alarm_config | 51 | severity | info |
| 803 | alarm_config | 51 | serviceAffecting | false |
| 804 | alarm_config | 51 | extNumber | 2.0002.20 |
| 805 | alarm_config | 51 | conditionType | RX-PWR-LOW-WN |
| 806 | alarm_config | 51 | amoType | SFP.2 |
| 807 | alarm_config | 51 | on | 0 |
| 808 | alarm_config | 52 | id | 52 |
| 809 | alarm_config | 52 | number | 2000221 |
| 810 | alarm_config | 52 | description | SFP-2 not present |
| 811 | alarm_config | 52 | enabled | true |
| 812 | alarm_config | 52 | severity | major |
| 813 | alarm_config | 52 | serviceAffecting | false |
| 814 | alarm_config | 52 | extNumber | 2.0002.21 |
| 815 | alarm_config | 52 | conditionType | MOD-NOT-PRESENT |
| 816 | alarm_config | 52 | amoType | SFP.2 |
| 817 | alarm_config | 52 | on | 0 |
| 818 | alarm_config | 53 | id | 53 |
| 819 | alarm_config | 53 | number | 2000301 |
| 820 | alarm_config | 53 | description | SFP-3 temperature high alarm |
| 821 | alarm_config | 53 | enabled | true |
| 822 | alarm_config | 53 | severity | major |
| 823 | alarm_config | 53 | serviceAffecting | false |
| 824 | alarm_config | 53 | extNumber | 2.0003.01 |
| 825 | alarm_config | 53 | conditionType | TEMP-HIGH-ALM |
| 826 | alarm_config | 53 | amoType | SFP.3 |
| 827 | alarm_config | 53 | on | 0 |
| 828 | alarm_config | 54 | id | 54 |
| 829 | alarm_config | 54 | number | 2000302 |
| 830 | alarm_config | 54 | description | SFP-3 temperature low alarm |
| 831 | alarm_config | 54 | enabled | true |
| 832 | alarm_config | 54 | severity | major |
| 833 | alarm_config | 54 | serviceAffecting | false |
| 834 | alarm_config | 54 | extNumber | 2.0003.02 |
| 835 | alarm_config | 54 | conditionType | TEMP-LOW-ALM |
| 836 | alarm_config | 54 | amoType | SFP.3 |
| 837 | alarm_config | 54 | on | 0 |
| 838 | alarm_config | 55 | id | 55 |
| 839 | alarm_config | 55 | number | 2000303 |
| 840 | alarm_config | 55 | description | SFP-3 temperature high warning |
| 841 | alarm_config | 55 | enabled | true |
| 842 | alarm_config | 55 | severity | info |
| 843 | alarm_config | 55 | serviceAffecting | false |
| 844 | alarm_config | 55 | extNumber | 2.0003.03 |
| 845 | alarm_config | 55 | conditionType | TEMP-HIGH-WN |
| 846 | alarm_config | 55 | amoType | SFP.3 |
| 847 | alarm_config | 55 | on | 0 |
| 848 | alarm_config | 56 | id | 56 |
| 849 | alarm_config | 56 | number | 2000304 |
| 850 | alarm_config | 56 | description | SFP-3 temperature low warning |
| 851 | alarm_config | 56 | enabled | true |
| 852 | alarm_config | 56 | severity | info |
| 853 | alarm_config | 56 | serviceAffecting | false |
| 854 | alarm_config | 56 | extNumber | 2.0003.04 |
| 855 | alarm_config | 56 | conditionType | TEMP-LOW-WN |
| 856 | alarm_config | 56 | amoType | SFP.3 |
| 857 | alarm_config | 56 | on | 0 |
| 858 | alarm_config | 57 | id | 57 |
| 859 | alarm_config | 57 | number | 2000305 |
| 860 | alarm_config | 57 | description | SFP-3 supply voltage high alarm |
| 861 | alarm_config | 57 | enabled | true |
| 862 | alarm_config | 57 | severity | major |
| 863 | alarm_config | 57 | serviceAffecting | false |
| 864 | alarm_config | 57 | extNumber | 2.0003.05 |
| 865 | alarm_config | 57 | conditionType | VCC-HIGH-ALM |
| 866 | alarm_config | 57 | amoType | SFP.3 |
| 867 | alarm_config | 57 | on | 0 |
| 868 | alarm_config | 58 | id | 58 |
| 869 | alarm_config | 58 | number | 2000306 |
| 870 | alarm_config | 58 | description | SFP-3 supply voltage low alarm |
| 871 | alarm_config | 58 | enabled | true |
| 872 | alarm_config | 58 | severity | major |
| 873 | alarm_config | 58 | serviceAffecting | false |
| 874 | alarm_config | 58 | extNumber | 2.0003.06 |
| 875 | alarm_config | 58 | conditionType | VCC-LOW-ALM |
| 876 | alarm_config | 58 | amoType | SFP.3 |
| 877 | alarm_config | 58 | on | 0 |
| 878 | alarm_config | 59 | id | 59 |
| 879 | alarm_config | 59 | number | 2000307 |
| 880 | alarm_config | 59 | description | SFP-3 supply voltage high warning |
| 881 | alarm_config | 59 | enabled | true |
| 882 | alarm_config | 59 | severity | info |
| 883 | alarm_config | 59 | serviceAffecting | false |
| 884 | alarm_config | 59 | extNumber | 2.0003.07 |
| 885 | alarm_config | 59 | conditionType | VCC-HIGH-WN |
| 886 | alarm_config | 59 | amoType | SFP.3 |
| 887 | alarm_config | 59 | on | 0 |
| 888 | alarm_config | 60 | id | 60 |
| 889 | alarm_config | 60 | number | 2000308 |
| 890 | alarm_config | 60 | description | SFP-3 supply voltage low warning |
| 891 | alarm_config | 60 | enabled | true |
| 892 | alarm_config | 60 | severity | info |
| 893 | alarm_config | 60 | serviceAffecting | false |
| 894 | alarm_config | 60 | extNumber | 2.0003.08 |
| 895 | alarm_config | 60 | conditionType | VCC-LOW-WN |
| 896 | alarm_config | 60 | amoType | SFP.3 |
| 897 | alarm_config | 60 | on | 0 |
| 898 | alarm_config | 61 | id | 61 |
| 899 | alarm_config | 61 | number | 2000309 |
| 900 | alarm_config | 61 | description | SFP-3 laser bias current high alarm |
| 901 | alarm_config | 61 | enabled | true |
| 902 | alarm_config | 61 | severity | major |
| 903 | alarm_config | 61 | serviceAffecting | false |
| 904 | alarm_config | 61 | extNumber | 2.0003.09 |
| 905 | alarm_config | 61 | conditionType | LBC-HIGH-ALM |
| 906 | alarm_config | 61 | amoType | SFP.3 |
| 907 | alarm_config | 61 | on | 0 |
| 908 | alarm_config | 62 | id | 62 |
| 909 | alarm_config | 62 | number | 2000310 |
| 910 | alarm_config | 62 | description | SFP-3 laser bias current low alarm |
| 911 | alarm_config | 62 | enabled | true |
| 912 | alarm_config | 62 | severity | major |
| 913 | alarm_config | 62 | serviceAffecting | false |
| 914 | alarm_config | 62 | extNumber | 2.0003.10 |
| 915 | alarm_config | 62 | conditionType | LBC-LOW-ALM |
| 916 | alarm_config | 62 | amoType | SFP.3 |
| 917 | alarm_config | 62 | on | 0 |
| 918 | alarm_config | 63 | id | 63 |
| 919 | alarm_config | 63 | number | 2000311 |
| 920 | alarm_config | 63 | description | SFP-3 laser bias current high warning |
| 921 | alarm_config | 63 | enabled | true |
| 922 | alarm_config | 63 | severity | info |
| 923 | alarm_config | 63 | serviceAffecting | false |
| 924 | alarm_config | 63 | extNumber | 2.0003.11 |
| 925 | alarm_config | 63 | conditionType | LBC-HIGH-WN |
| 926 | alarm_config | 63 | amoType | SFP.3 |
| 927 | alarm_config | 63 | on | 0 |
| 928 | alarm_config | 64 | id | 64 |
| 929 | alarm_config | 64 | number | 2000312 |
| 930 | alarm_config | 64 | description | SFP-3 laser bias current low warning |
| 931 | alarm_config | 64 | enabled | true |
| 932 | alarm_config | 64 | severity | info |
| 933 | alarm_config | 64 | serviceAffecting | false |
| 934 | alarm_config | 64 | extNumber | 2.0003.12 |
| 935 | alarm_config | 64 | conditionType | LBC-LOW-WN |
| 936 | alarm_config | 64 | amoType | SFP.3 |
| 937 | alarm_config | 64 | on | 0 |
| 938 | alarm_config | 65 | id | 65 |
| 939 | alarm_config | 65 | number | 2000313 |
| 940 | alarm_config | 65 | description | SFP-3 transmit power high alarm |
| 941 | alarm_config | 65 | enabled | true |
| 942 | alarm_config | 65 | severity | major |
| 943 | alarm_config | 65 | serviceAffecting | false |
| 944 | alarm_config | 65 | extNumber | 2.0003.13 |
| 945 | alarm_config | 65 | conditionType | TX-PWR-HIGH-ALM |
| 946 | alarm_config | 65 | amoType | SFP.3 |
| 947 | alarm_config | 65 | on | 0 |
| 948 | alarm_config | 66 | id | 66 |
| 949 | alarm_config | 66 | number | 2000314 |
| 950 | alarm_config | 66 | description | SFP-3 transmit power low alarm |
| 951 | alarm_config | 66 | enabled | true |
| 952 | alarm_config | 66 | severity | major |
| 953 | alarm_config | 66 | serviceAffecting | false |
| 954 | alarm_config | 66 | extNumber | 2.0003.14 |
| 955 | alarm_config | 66 | conditionType | TX-PWR-LOW-ALM |
| 956 | alarm_config | 66 | amoType | SFP.3 |
| 957 | alarm_config | 66 | on | 0 |
| 958 | alarm_config | 67 | id | 67 |
| 959 | alarm_config | 67 | number | 2000315 |
| 960 | alarm_config | 67 | description | SFP-3 transmit power high warning |
| 961 | alarm_config | 67 | enabled | true |
| 962 | alarm_config | 67 | severity | info |
| 963 | alarm_config | 67 | serviceAffecting | false |
| 964 | alarm_config | 67 | extNumber | 2.0003.15 |
| 965 | alarm_config | 67 | conditionType | TX-PWR-HIGH-WN |
| 966 | alarm_config | 67 | amoType | SFP.3 |
| 967 | alarm_config | 67 | on | 0 |
| 968 | alarm_config | 68 | id | 68 |
| 969 | alarm_config | 68 | number | 2000316 |
| 970 | alarm_config | 68 | description | SFP-3 transmit power low warning |
| 971 | alarm_config | 68 | enabled | true |
| 972 | alarm_config | 68 | severity | info |
| 973 | alarm_config | 68 | serviceAffecting | false |
| 974 | alarm_config | 68 | extNumber | 2.0003.16 |
| 975 | alarm_config | 68 | conditionType | TX-PWR-LOW-WN |
| 976 | alarm_config | 68 | amoType | SFP.3 |
| 977 | alarm_config | 68 | on | 0 |
| 978 | alarm_config | 69 | id | 69 |
| 979 | alarm_config | 69 | number | 2000317 |
| 980 | alarm_config | 69 | description | SFP-3 receive power high alarm |
| 981 | alarm_config | 69 | enabled | true |
| 982 | alarm_config | 69 | severity | major |
| 983 | alarm_config | 69 | serviceAffecting | false |
| 984 | alarm_config | 69 | extNumber | 2.0003.17 |
| 985 | alarm_config | 69 | conditionType | RX-PWR-HIGH-ALM |
| 986 | alarm_config | 69 | amoType | SFP.3 |
| 987 | alarm_config | 69 | on | 0 |
| 988 | alarm_config | 70 | id | 70 |
| 989 | alarm_config | 70 | number | 2000318 |
| 990 | alarm_config | 70 | description | SFP-3 receive power low alarm |
| 991 | alarm_config | 70 | enabled | true |
| 992 | alarm_config | 70 | severity | major |
| 993 | alarm_config | 70 | serviceAffecting | false |
| 994 | alarm_config | 70 | extNumber | 2.0003.18 |
| 995 | alarm_config | 70 | conditionType | RX-PWR-LOW-ALM |
| 996 | alarm_config | 70 | amoType | SFP.3 |
| 997 | alarm_config | 70 | on | 0 |
| 998 | alarm_config | 71 | id | 71 |
| 999 | alarm_config | 71 | number | 2000319 |
| 1000 | alarm_config | 71 | description | SFP-3 receive power high warning |
| 1001 | alarm_config | 71 | enabled | true |
| 1002 | alarm_config | 71 | severity | info |
| 1003 | alarm_config | 71 | serviceAffecting | false |
| 1004 | alarm_config | 71 | extNumber | 2.0003.19 |
| 1005 | alarm_config | 71 | conditionType | RX-PWR-HIGH-WN |
| 1006 | alarm_config | 71 | amoType | SFP.3 |
| 1007 | alarm_config | 71 | on | 0 |
| 1008 | alarm_config | 72 | id | 72 |
| 1009 | alarm_config | 72 | number | 2000320 |
| 1010 | alarm_config | 72 | description | SFP-3 receive power low warning |
| 1011 | alarm_config | 72 | enabled | true |
| 1012 | alarm_config | 72 | severity | info |
| 1013 | alarm_config | 72 | serviceAffecting | false |
| 1014 | alarm_config | 72 | extNumber | 2.0003.20 |
| 1015 | alarm_config | 72 | conditionType | RX-PWR-LOW-WN |
| 1016 | alarm_config | 72 | amoType | SFP.3 |
| 1017 | alarm_config | 72 | on | 0 |
| 1018 | alarm_config | 73 | id | 73 |
| 1019 | alarm_config | 73 | number | 2000321 |
| 1020 | alarm_config | 73 | description | SFP-3 not present |
| 1021 | alarm_config | 73 | enabled | true |
| 1022 | alarm_config | 73 | severity | major |
| 1023 | alarm_config | 73 | serviceAffecting | false |
| 1024 | alarm_config | 73 | extNumber | 2.0003.21 |
| 1025 | alarm_config | 73 | conditionType | MOD-NOT-PRESENT |
| 1026 | alarm_config | 73 | amoType | SFP.3 |
| 1027 | alarm_config | 73 | on | 0 |
| 1028 | alarm_config | 74 | id | 74 |
| 1029 | alarm_config | 74 | number | 2000401 |
| 1030 | alarm_config | 74 | description | SFP-4 temperature high alarm |
| 1031 | alarm_config | 74 | enabled | true |
| 1032 | alarm_config | 74 | severity | major |
| 1033 | alarm_config | 74 | serviceAffecting | false |
| 1034 | alarm_config | 74 | extNumber | 2.0004.01 |
| 1035 | alarm_config | 74 | conditionType | TEMP-HIGH-ALM |
| 1036 | alarm_config | 74 | amoType | SFP.4 |
| 1037 | alarm_config | 74 | on | 0 |
| 1038 | alarm_config | 75 | id | 75 |
| 1039 | alarm_config | 75 | number | 2000402 |
| 1040 | alarm_config | 75 | description | SFP-4 temperature low alarm |
| 1041 | alarm_config | 75 | enabled | true |
| 1042 | alarm_config | 75 | severity | major |
| 1043 | alarm_config | 75 | serviceAffecting | false |
| 1044 | alarm_config | 75 | extNumber | 2.0004.02 |
| 1045 | alarm_config | 75 | conditionType | TEMP-LOW-ALM |
| 1046 | alarm_config | 75 | amoType | SFP.4 |
| 1047 | alarm_config | 75 | on | 0 |
| 1048 | alarm_config | 76 | id | 76 |
| 1049 | alarm_config | 76 | number | 2000403 |
| 1050 | alarm_config | 76 | description | SFP-4 temperature high warning |
| 1051 | alarm_config | 76 | enabled | true |
| 1052 | alarm_config | 76 | severity | info |
| 1053 | alarm_config | 76 | serviceAffecting | false |
| 1054 | alarm_config | 76 | extNumber | 2.0004.03 |
| 1055 | alarm_config | 76 | conditionType | TEMP-HIGH-WN |
| 1056 | alarm_config | 76 | amoType | SFP.4 |
| 1057 | alarm_config | 76 | on | 0 |
| 1058 | alarm_config | 77 | id | 77 |
| 1059 | alarm_config | 77 | number | 2000404 |
| 1060 | alarm_config | 77 | description | SFP-4 temperature low warning |
| 1061 | alarm_config | 77 | enabled | true |
| 1062 | alarm_config | 77 | severity | info |
| 1063 | alarm_config | 77 | serviceAffecting | false |
| 1064 | alarm_config | 77 | extNumber | 2.0004.04 |
| 1065 | alarm_config | 77 | conditionType | TEMP-LOW-WN |
| 1066 | alarm_config | 77 | amoType | SFP.4 |
| 1067 | alarm_config | 77 | on | 0 |
| 1068 | alarm_config | 78 | id | 78 |
| 1069 | alarm_config | 78 | number | 2000405 |
| 1070 | alarm_config | 78 | description | SFP-4 supply voltage high alarm |
| 1071 | alarm_config | 78 | enabled | true |
| 1072 | alarm_config | 78 | severity | major |
| 1073 | alarm_config | 78 | serviceAffecting | false |
| 1074 | alarm_config | 78 | extNumber | 2.0004.05 |
| 1075 | alarm_config | 78 | conditionType | VCC-HIGH-ALM |
| 1076 | alarm_config | 78 | amoType | SFP.4 |
| 1077 | alarm_config | 78 | on | 0 |
| 1078 | alarm_config | 79 | id | 79 |
| 1079 | alarm_config | 79 | number | 2000406 |
| 1080 | alarm_config | 79 | description | SFP-4 supply voltage low alarm |
| 1081 | alarm_config | 79 | enabled | true |
| 1082 | alarm_config | 79 | severity | major |
| 1083 | alarm_config | 79 | serviceAffecting | false |
| 1084 | alarm_config | 79 | extNumber | 2.0004.06 |
| 1085 | alarm_config | 79 | conditionType | VCC-LOW-ALM |
| 1086 | alarm_config | 79 | amoType | SFP.4 |
| 1087 | alarm_config | 79 | on | 0 |
| 1088 | alarm_config | 80 | id | 80 |
| 1089 | alarm_config | 80 | number | 2000407 |
| 1090 | alarm_config | 80 | description | SFP-4 supply voltage high warning |
| 1091 | alarm_config | 80 | enabled | true |
| 1092 | alarm_config | 80 | severity | info |
| 1093 | alarm_config | 80 | serviceAffecting | false |
| 1094 | alarm_config | 80 | extNumber | 2.0004.07 |
| 1095 | alarm_config | 80 | conditionType | VCC-HIGH-WN |
| 1096 | alarm_config | 80 | amoType | SFP.4 |
| 1097 | alarm_config | 80 | on | 0 |
| 1098 | alarm_config | 81 | id | 81 |
| 1099 | alarm_config | 81 | number | 2000408 |
| 1100 | alarm_config | 81 | description | SFP-4 supply voltage low warning |
| 1101 | alarm_config | 81 | enabled | true |
| 1102 | alarm_config | 81 | severity | info |
| 1103 | alarm_config | 81 | serviceAffecting | false |
| 1104 | alarm_config | 81 | extNumber | 2.0004.08 |
| 1105 | alarm_config | 81 | conditionType | VCC-LOW-WN |
| 1106 | alarm_config | 81 | amoType | SFP.4 |
| 1107 | alarm_config | 81 | on | 0 |
| 1108 | alarm_config | 82 | id | 82 |
| 1109 | alarm_config | 82 | number | 2000409 |
| 1110 | alarm_config | 82 | description | SFP-4 laser bias current high alarm |
| 1111 | alarm_config | 82 | enabled | true |
| 1112 | alarm_config | 82 | severity | major |
| 1113 | alarm_config | 82 | serviceAffecting | false |
| 1114 | alarm_config | 82 | extNumber | 2.0004.09 |
| 1115 | alarm_config | 82 | conditionType | LBC-HIGH-ALM |
| 1116 | alarm_config | 82 | amoType | SFP.4 |
| 1117 | alarm_config | 82 | on | 0 |
| 1118 | alarm_config | 83 | id | 83 |
| 1119 | alarm_config | 83 | number | 2000410 |
| 1120 | alarm_config | 83 | description | SFP-4 laser bias current low alarm |
| 1121 | alarm_config | 83 | enabled | true |
| 1122 | alarm_config | 83 | severity | major |
| 1123 | alarm_config | 83 | serviceAffecting | false |
| 1124 | alarm_config | 83 | extNumber | 2.0004.10 |
| 1125 | alarm_config | 83 | conditionType | LBC-LOW-ALM |
| 1126 | alarm_config | 83 | amoType | SFP.4 |
| 1127 | alarm_config | 83 | on | 0 |
| 1128 | alarm_config | 84 | id | 84 |
| 1129 | alarm_config | 84 | number | 2000411 |
| 1130 | alarm_config | 84 | description | SFP-4 laser bias current high warning |
| 1131 | alarm_config | 84 | enabled | true |
| 1132 | alarm_config | 84 | severity | info |
| 1133 | alarm_config | 84 | serviceAffecting | false |
| 1134 | alarm_config | 84 | extNumber | 2.0004.11 |
| 1135 | alarm_config | 84 | conditionType | LBC-HIGH-WN |
| 1136 | alarm_config | 84 | amoType | SFP.4 |
| 1137 | alarm_config | 84 | on | 0 |
| 1138 | alarm_config | 85 | id | 85 |
| 1139 | alarm_config | 85 | number | 2000412 |
| 1140 | alarm_config | 85 | description | SFP-4 laser bias current low warning |
| 1141 | alarm_config | 85 | enabled | true |
| 1142 | alarm_config | 85 | severity | info |
| 1143 | alarm_config | 85 | serviceAffecting | false |
| 1144 | alarm_config | 85 | extNumber | 2.0004.12 |
| 1145 | alarm_config | 85 | conditionType | LBC-LOW-WN |
| 1146 | alarm_config | 85 | amoType | SFP.4 |
| 1147 | alarm_config | 85 | on | 0 |
| 1148 | alarm_config | 86 | id | 86 |
| 1149 | alarm_config | 86 | number | 2000413 |
| 1150 | alarm_config | 86 | description | SFP-4 transmit power high alarm |
| 1151 | alarm_config | 86 | enabled | true |
| 1152 | alarm_config | 86 | severity | major |
| 1153 | alarm_config | 86 | serviceAffecting | false |
| 1154 | alarm_config | 86 | extNumber | 2.0004.13 |
| 1155 | alarm_config | 86 | conditionType | TX-PWR-HIGH-ALM |
| 1156 | alarm_config | 86 | amoType | SFP.4 |
| 1157 | alarm_config | 86 | on | 0 |
| 1158 | alarm_config | 87 | id | 87 |
| 1159 | alarm_config | 87 | number | 2000414 |
| 1160 | alarm_config | 87 | description | SFP-4 transmit power low alarm |
| 1161 | alarm_config | 87 | enabled | true |
| 1162 | alarm_config | 87 | severity | major |
| 1163 | alarm_config | 87 | serviceAffecting | false |
| 1164 | alarm_config | 87 | extNumber | 2.0004.14 |
| 1165 | alarm_config | 87 | conditionType | TX-PWR-LOW-ALM |
| 1166 | alarm_config | 87 | amoType | SFP.4 |
| 1167 | alarm_config | 87 | on | 0 |
| 1168 | alarm_config | 88 | id | 88 |
| 1169 | alarm_config | 88 | number | 2000415 |
| 1170 | alarm_config | 88 | description | SFP-4 transmit power high warning |
| 1171 | alarm_config | 88 | enabled | true |
| 1172 | alarm_config | 88 | severity | info |
| 1173 | alarm_config | 88 | serviceAffecting | false |
| 1174 | alarm_config | 88 | extNumber | 2.0004.15 |
| 1175 | alarm_config | 88 | conditionType | TX-PWR-HIGH-WN |
| 1176 | alarm_config | 88 | amoType | SFP.4 |
| 1177 | alarm_config | 88 | on | 0 |
| 1178 | alarm_config | 89 | id | 89 |
| 1179 | alarm_config | 89 | number | 2000416 |
| 1180 | alarm_config | 89 | description | SFP-4 transmit power low warning |
| 1181 | alarm_config | 89 | enabled | true |
| 1182 | alarm_config | 89 | severity | info |
| 1183 | alarm_config | 89 | serviceAffecting | false |
| 1184 | alarm_config | 89 | extNumber | 2.0004.16 |
| 1185 | alarm_config | 89 | conditionType | TX-PWR-LOW-WN |
| 1186 | alarm_config | 89 | amoType | SFP.4 |
| 1187 | alarm_config | 89 | on | 0 |
| 1188 | alarm_config | 90 | id | 90 |
| 1189 | alarm_config | 90 | number | 2000417 |
| 1190 | alarm_config | 90 | description | SFP-4 receive power high alarm |
| 1191 | alarm_config | 90 | enabled | true |
| 1192 | alarm_config | 90 | severity | major |
| 1193 | alarm_config | 90 | serviceAffecting | false |
| 1194 | alarm_config | 90 | extNumber | 2.0004.17 |
| 1195 | alarm_config | 90 | conditionType | RX-PWR-HIGH-ALM |
| 1196 | alarm_config | 90 | amoType | SFP.4 |
| 1197 | alarm_config | 90 | on | 0 |
| 1198 | alarm_config | 91 | id | 91 |
| 1199 | alarm_config | 91 | number | 2000418 |
| 1200 | alarm_config | 91 | description | SFP-4 receive power low alarm |
| 1201 | alarm_config | 91 | enabled | true |
| 1202 | alarm_config | 91 | severity | major |
| 1203 | alarm_config | 91 | serviceAffecting | false |
| 1204 | alarm_config | 91 | extNumber | 2.0004.18 |
| 1205 | alarm_config | 91 | conditionType | RX-PWR-LOW-ALM |
| 1206 | alarm_config | 91 | amoType | SFP.4 |
| 1207 | alarm_config | 91 | on | 0 |
| 1208 | alarm_config | 92 | id | 92 |
| 1209 | alarm_config | 92 | number | 2000419 |
| 1210 | alarm_config | 92 | description | SFP-4 receive power high warning |
| 1211 | alarm_config | 92 | enabled | true |
| 1212 | alarm_config | 92 | severity | info |
| 1213 | alarm_config | 92 | serviceAffecting | false |
| 1214 | alarm_config | 92 | extNumber | 2.0004.19 |
| 1215 | alarm_config | 92 | conditionType | RX-PWR-HIGH-WN |
| 1216 | alarm_config | 92 | amoType | SFP.4 |
| 1217 | alarm_config | 92 | on | 0 |
| 1218 | alarm_config | 93 | id | 93 |
| 1219 | alarm_config | 93 | number | 2000420 |
| 1220 | alarm_config | 93 | description | SFP-4 receive power low warning |
| 1221 | alarm_config | 93 | enabled | true |
| 1222 | alarm_config | 93 | severity | info |
| 1223 | alarm_config | 93 | serviceAffecting | false |
| 1224 | alarm_config | 93 | extNumber | 2.0004.20 |
| 1225 | alarm_config | 93 | conditionType | RX-PWR-LOW-WN |
| 1226 | alarm_config | 93 | amoType | SFP.4 |
| 1227 | alarm_config | 93 | on | 0 |
| 1228 | alarm_config | 94 | id | 94 |
| 1229 | alarm_config | 94 | number | 2000421 |
| 1230 | alarm_config | 94 | description | SFP-4 not present |
| 1231 | alarm_config | 94 | enabled | true |
| 1232 | alarm_config | 94 | severity | major |
| 1233 | alarm_config | 94 | serviceAffecting | false |
| 1234 | alarm_config | 94 | extNumber | 2.0004.21 |
| 1235 | alarm_config | 94 | conditionType | MOD-NOT-PRESENT |
| 1236 | alarm_config | 94 | amoType | SFP.4 |
| 1237 | alarm_config | 94 | on | 0 |
| 1238 | alarm_config | 95 | id | 95 |
| 1239 | alarm_config | 95 | number | 1000101 |
| 1240 | alarm_config | 95 | description | Link down on EVEN_VLAN_UPLINK port |
| 1241 | alarm_config | 95 | enabled | true |
| 1242 | alarm_config | 95 | severity | major |
| 1243 | alarm_config | 95 | serviceAffecting | false |
| 1244 | alarm_config | 95 | extNumber | 1.0001.01 |
| 1245 | alarm_config | 95 | conditionType | LINK-DOWN |
| 1246 | alarm_config | 95 | amoType | PORT.EVEN_VLAN_UPLINK |
| 1247 | alarm_config | 95 | on | 0 |
| 1248 | alarm_config | 96 | id | 96 |
| 1249 | alarm_config | 96 | number | 1000102 |
| 1250 | alarm_config | 96 | description | Loopback on port EVEN_VLAN_UPLINK |
| 1251 | alarm_config | 96 | enabled | true |
| 1252 | alarm_config | 96 | severity | info |
| 1253 | alarm_config | 96 | serviceAffecting | false |
| 1254 | alarm_config | 96 | extNumber | 1.0001.02 |
| 1255 | alarm_config | 96 | conditionType | OAM-LOOPBACK |
| 1256 | alarm_config | 96 | amoType | PORT.EVEN_VLAN_UPLINK |
| 1257 | alarm_config | 96 | on | 0 |
| 1258 | alarm_config | 97 | id | 97 |
| 1259 | alarm_config | 97 | number | 1000104 |
| 1260 | alarm_config | 97 | description | Fault propagation caused link down on port EVEN_VLAN_UPLINK |
| 1261 | alarm_config | 97 | enabled | true |
| 1262 | alarm_config | 97 | severity | major |
| 1263 | alarm_config | 97 | serviceAffecting | true |
| 1264 | alarm_config | 97 | extNumber | 1.0001.04 |
| 1265 | alarm_config | 97 | conditionType | LINK-DOWN-FP |
| 1266 | alarm_config | 97 | amoType | PORT.EVEN_VLAN_UPLINK |
| 1267 | alarm_config | 97 | on | 0 |
| 1268 | alarm_config | 98 | id | 98 |
| 1269 | alarm_config | 98 | number | 1000107 |
| 1270 | alarm_config | 98 | description | SA caused link down on port EVEN_VLAN_UPLINK |
| 1271 | alarm_config | 98 | enabled | true |
| 1272 | alarm_config | 98 | severity | major |
| 1273 | alarm_config | 98 | serviceAffecting | true |
| 1274 | alarm_config | 98 | extNumber | 1.0001.07 |
| 1275 | alarm_config | 98 | conditionType | LINK-DOWN-SA |
| 1276 | alarm_config | 98 | amoType | PORT.EVEN_VLAN_UPLINK |
| 1277 | alarm_config | 98 | on | 0 |
| 1278 | alarm_config | 99 | id | 99 |
| 1279 | alarm_config | 99 | number | 1000201 |
| 1280 | alarm_config | 99 | description | Link down on ODD_VLAN_UPLINK port |
| 1281 | alarm_config | 99 | enabled | true |
| 1282 | alarm_config | 99 | severity | major |
| 1283 | alarm_config | 99 | serviceAffecting | false |
| 1284 | alarm_config | 99 | extNumber | 1.0002.01 |
| 1285 | alarm_config | 99 | conditionType | LINK-DOWN |
| 1286 | alarm_config | 99 | amoType | PORT.ODD_VLAN_UPLINK |
| 1287 | alarm_config | 99 | on | 0 |
| 1288 | alarm_config | 100 | id | 100 |
| 1289 | alarm_config | 100 | number | 1000202 |
| 1290 | alarm_config | 100 | description | Loopback on port ODD_VLAN_UPLINK |
| 1291 | alarm_config | 100 | enabled | true |
| 1292 | alarm_config | 100 | severity | info |
| 1293 | alarm_config | 100 | serviceAffecting | false |
| 1294 | alarm_config | 100 | extNumber | 1.0002.02 |
| 1295 | alarm_config | 100 | conditionType | OAM-LOOPBACK |
| 1296 | alarm_config | 100 | amoType | PORT.ODD_VLAN_UPLINK |
| 1297 | alarm_config | 100 | on | 0 |
| 1298 | alarm_config | 101 | id | 101 |
| 1299 | alarm_config | 101 | number | 1000204 |
| 1300 | alarm_config | 101 | description | Fault propagation caused link down on port ODD_VLAN_UPLINK |
| 1301 | alarm_config | 101 | enabled | true |
| 1302 | alarm_config | 101 | severity | major |
| 1303 | alarm_config | 101 | serviceAffecting | true |
| 1304 | alarm_config | 101 | extNumber | 1.0002.04 |
| 1305 | alarm_config | 101 | conditionType | LINK-DOWN-FP |
| 1306 | alarm_config | 101 | amoType | PORT.ODD_VLAN_UPLINK |
| 1307 | alarm_config | 101 | on | 0 |
| 1308 | alarm_config | 102 | id | 102 |
| 1309 | alarm_config | 102 | number | 1000207 |
| 1310 | alarm_config | 102 | description | SA caused link down on port ODD_VLAN_UPLINK |
| 1311 | alarm_config | 102 | enabled | true |
| 1312 | alarm_config | 102 | severity | major |
| 1313 | alarm_config | 102 | serviceAffecting | true |
| 1314 | alarm_config | 102 | extNumber | 1.0002.07 |
| 1315 | alarm_config | 102 | conditionType | LINK-DOWN-SA |
| 1316 | alarm_config | 102 | amoType | PORT.ODD_VLAN_UPLINK |
| 1317 | alarm_config | 102 | on | 0 |
| 1318 | alarm_config | 103 | id | 103 |
| 1319 | alarm_config | 103 | number | 1000301 |
| 1320 | alarm_config | 103 | description | Link down on EVEN_VLAN_DOWNLIN port |
| 1321 | alarm_config | 103 | enabled | true |
| 1322 | alarm_config | 103 | severity | major |
| 1323 | alarm_config | 103 | serviceAffecting | false |
| 1324 | alarm_config | 103 | extNumber | 1.0003.01 |
| 1325 | alarm_config | 103 | conditionType | LINK-DOWN |
| 1326 | alarm_config | 103 | amoType | PORT.EVEN_VLAN_DOWNLIN |
| 1327 | alarm_config | 103 | on | 0 |
| 1328 | alarm_config | 104 | id | 104 |
| 1329 | alarm_config | 104 | number | 1000302 |
| 1330 | alarm_config | 104 | description | Loopback on port EVEN_VLAN_DOWNLIN |
| 1331 | alarm_config | 104 | enabled | true |
| 1332 | alarm_config | 104 | severity | info |
| 1333 | alarm_config | 104 | serviceAffecting | false |
| 1334 | alarm_config | 104 | extNumber | 1.0003.02 |
| 1335 | alarm_config | 104 | conditionType | OAM-LOOPBACK |
| 1336 | alarm_config | 104 | amoType | PORT.EVEN_VLAN_DOWNLIN |
| 1337 | alarm_config | 104 | on | 0 |
| 1338 | alarm_config | 105 | id | 105 |
| 1339 | alarm_config | 105 | number | 1000304 |
| 1340 | alarm_config | 105 | description | Fault propagation caused link down on port EVEN_VLAN_DOWNLIN |
| 1341 | alarm_config | 105 | enabled | true |
| 1342 | alarm_config | 105 | severity | major |
| 1343 | alarm_config | 105 | serviceAffecting | true |
| 1344 | alarm_config | 105 | extNumber | 1.0003.04 |
| 1345 | alarm_config | 105 | conditionType | LINK-DOWN-FP |
| 1346 | alarm_config | 105 | amoType | PORT.EVEN_VLAN_DOWNLIN |
| 1347 | alarm_config | 105 | on | 0 |
| 1348 | alarm_config | 106 | id | 106 |
| 1349 | alarm_config | 106 | number | 1000307 |
| 1350 | alarm_config | 106 | description | SA caused link down on port EVEN_VLAN_DOWNLIN |
| 1351 | alarm_config | 106 | enabled | true |
| 1352 | alarm_config | 106 | severity | major |
| 1353 | alarm_config | 106 | serviceAffecting | true |
| 1354 | alarm_config | 106 | extNumber | 1.0003.07 |
| 1355 | alarm_config | 106 | conditionType | LINK-DOWN-SA |
| 1356 | alarm_config | 106 | amoType | PORT.EVEN_VLAN_DOWNLIN |
| 1357 | alarm_config | 106 | on | 0 |
| 1358 | alarm_config | 107 | id | 107 |
| 1359 | alarm_config | 107 | number | 1000401 |
| 1360 | alarm_config | 107 | description | Link down on ODD_VLAN_DOWNLINK port |
| 1361 | alarm_config | 107 | enabled | true |
| 1362 | alarm_config | 107 | severity | major |
| 1363 | alarm_config | 107 | serviceAffecting | false |
| 1364 | alarm_config | 107 | extNumber | 1.0004.01 |
| 1365 | alarm_config | 107 | conditionType | LINK-DOWN |
| 1366 | alarm_config | 107 | amoType | PORT.ODD_VLAN_DOWNLINK |
| 1367 | alarm_config | 107 | on | 0 |
| 1368 | alarm_config | 108 | id | 108 |
| 1369 | alarm_config | 108 | number | 1000402 |
| 1370 | alarm_config | 108 | description | Loopback on port ODD_VLAN_DOWNLINK |
| 1371 | alarm_config | 108 | enabled | true |
| 1372 | alarm_config | 108 | severity | info |
| 1373 | alarm_config | 108 | serviceAffecting | false |
| 1374 | alarm_config | 108 | extNumber | 1.0004.02 |
| 1375 | alarm_config | 108 | conditionType | OAM-LOOPBACK |
| 1376 | alarm_config | 108 | amoType | PORT.ODD_VLAN_DOWNLINK |
| 1377 | alarm_config | 108 | on | 0 |
| 1378 | alarm_config | 109 | id | 109 |
| 1379 | alarm_config | 109 | number | 1000404 |
| 1380 | alarm_config | 109 | description | Fault propagation caused link down on port ODD_VLAN_DOWNLINK |
| 1381 | alarm_config | 109 | enabled | true |
| 1382 | alarm_config | 109 | severity | major |
| 1383 | alarm_config | 109 | serviceAffecting | true |
| 1384 | alarm_config | 109 | extNumber | 1.0004.04 |
| 1385 | alarm_config | 109 | conditionType | LINK-DOWN-FP |
| 1386 | alarm_config | 109 | amoType | PORT.ODD_VLAN_DOWNLINK |
| 1387 | alarm_config | 109 | on | 0 |
| 1388 | alarm_config | 110 | id | 110 |
| 1389 | alarm_config | 110 | number | 1000407 |
| 1390 | alarm_config | 110 | description | SA caused link down on port ODD_VLAN_DOWNLINK |
| 1391 | alarm_config | 110 | enabled | true |
| 1392 | alarm_config | 110 | severity | major |
| 1393 | alarm_config | 110 | serviceAffecting | true |
| 1394 | alarm_config | 110 | extNumber | 1.0004.07 |
| 1395 | alarm_config | 110 | conditionType | LINK-DOWN-SA |
| 1396 | alarm_config | 110 | amoType | PORT.ODD_VLAN_DOWNLINK |
| 1397 | alarm_config | 110 | on | 0 |
| 1398 | alarm_config | 111 | id | 111 |
| 1399 | alarm_config | 111 | number | 1000501 |
| 1400 | alarm_config | 111 | description | Link down on Management port |
| 1401 | alarm_config | 111 | enabled | false |
| 1402 | alarm_config | 111 | severity | major |
| 1403 | alarm_config | 111 | serviceAffecting | false |
| 1404 | alarm_config | 111 | extNumber | 1.0005.01 |
| 1405 | alarm_config | 111 | conditionType | LINK-DOWN |
| 1406 | alarm_config | 111 | amoType | PORT.Management |
| 1407 | alarm_config | 111 | on | 0 |
| 1408 | alarm_config | 112 | id | 112 |
| 1409 | alarm_config | 112 | number | 1000601 |
| 1410 | alarm_config | 112 | description | Link down on LAG-1 port |
| 1411 | alarm_config | 112 | enabled | true |
| 1412 | alarm_config | 112 | severity | major |
| 1413 | alarm_config | 112 | serviceAffecting | false |
| 1414 | alarm_config | 112 | extNumber | 1.0006.01 |
| 1415 | alarm_config | 112 | conditionType | LINK-DOWN |
| 1416 | alarm_config | 112 | amoType | PORT.LAG-1 |
| 1417 | alarm_config | 112 | on | 0 |
| 1418 | alarm_config | 113 | id | 113 |
| 1419 | alarm_config | 113 | number | 1000602 |
| 1420 | alarm_config | 113 | description | Loopback on port LAG-1 |
| 1421 | alarm_config | 113 | enabled | true |
| 1422 | alarm_config | 113 | severity | info |
| 1423 | alarm_config | 113 | serviceAffecting | false |
| 1424 | alarm_config | 113 | extNumber | 1.0006.02 |
| 1425 | alarm_config | 113 | conditionType | OAM-LOOPBACK |
| 1426 | alarm_config | 113 | amoType | PORT.LAG-1 |
| 1427 | alarm_config | 113 | on | 0 |
| 1428 | alarm_config | 114 | id | 114 |
| 1429 | alarm_config | 114 | number | 1000604 |
| 1430 | alarm_config | 114 | description | Fault propagation caused link down on port LAG-1 |
| 1431 | alarm_config | 114 | enabled | true |
| 1432 | alarm_config | 114 | severity | major |
| 1433 | alarm_config | 114 | serviceAffecting | true |
| 1434 | alarm_config | 114 | extNumber | 1.0006.04 |
| 1435 | alarm_config | 114 | conditionType | LINK-DOWN-FP |
| 1436 | alarm_config | 114 | amoType | PORT.LAG-1 |
| 1437 | alarm_config | 114 | on | 0 |
| 1438 | alarm_config | 115 | id | 115 |
| 1439 | alarm_config | 115 | number | 1000603 |
| 1440 | alarm_config | 115 | description | Sub-port speed mismatch on port LAG-1 |
| 1441 | alarm_config | 115 | enabled | true |
| 1442 | alarm_config | 115 | severity | major |
| 1443 | alarm_config | 115 | serviceAffecting | false |
| 1444 | alarm_config | 115 | extNumber | 1.0006.03 |
| 1445 | alarm_config | 115 | conditionType | SPEED-MISMATCH |
| 1446 | alarm_config | 115 | amoType | PORT.LAG-1 |
| 1447 | alarm_config | 115 | on | 0 |
| 1448 | alarm_config | 116 | id | 116 |
| 1449 | alarm_config | 116 | number | 1000701 |
| 1450 | alarm_config | 116 | description | Link down on LAG-2 port |
| 1451 | alarm_config | 116 | enabled | false |
| 1452 | alarm_config | 116 | severity | major |
| 1453 | alarm_config | 116 | serviceAffecting | false |
| 1454 | alarm_config | 116 | extNumber | 1.0007.01 |
| 1455 | alarm_config | 116 | conditionType | LINK-DOWN |
| 1456 | alarm_config | 116 | amoType | PORT.LAG-2 |
| 1457 | alarm_config | 116 | on | 0 |
| 1458 | alarm_config | 117 | id | 117 |
| 1459 | alarm_config | 117 | number | 1000702 |
| 1460 | alarm_config | 117 | description | Loopback on port LAG-2 |
| 1461 | alarm_config | 117 | enabled | true |
| 1462 | alarm_config | 117 | severity | info |
| 1463 | alarm_config | 117 | serviceAffecting | false |
| 1464 | alarm_config | 117 | extNumber | 1.0007.02 |
| 1465 | alarm_config | 117 | conditionType | OAM-LOOPBACK |
| 1466 | alarm_config | 117 | amoType | PORT.LAG-2 |
| 1467 | alarm_config | 117 | on | 0 |
| 1468 | alarm_config | 118 | id | 118 |
| 1469 | alarm_config | 118 | number | 1000704 |
| 1470 | alarm_config | 118 | description | Fault propagation caused link down on port LAG-2 |
| 1471 | alarm_config | 118 | enabled | true |
| 1472 | alarm_config | 118 | severity | major |
| 1473 | alarm_config | 118 | serviceAffecting | true |
| 1474 | alarm_config | 118 | extNumber | 1.0007.04 |
| 1475 | alarm_config | 118 | conditionType | LINK-DOWN-FP |
| 1476 | alarm_config | 118 | amoType | PORT.LAG-2 |
| 1477 | alarm_config | 118 | on | 0 |
| 1478 | alarm_config | 119 | id | 119 |
| 1479 | alarm_config | 119 | number | 1000703 |
| 1480 | alarm_config | 119 | description | Sub-port speed mismatch on port LAG-2 |
| 1481 | alarm_config | 119 | enabled | true |
| 1482 | alarm_config | 119 | severity | major |
| 1483 | alarm_config | 119 | serviceAffecting | false |
| 1484 | alarm_config | 119 | extNumber | 1.0007.03 |
| 1485 | alarm_config | 119 | conditionType | SPEED-MISMATCH |
| 1486 | alarm_config | 119 | amoType | PORT.LAG-2 |
| 1487 | alarm_config | 119 | on | 0 |
| 1488 | alarm_config | 120 | id | 120 |
| 1489 | alarm_config | 120 | number | 8000006 |
| 1490 | alarm_config | 120 | description | Input 1 Active |
| 1491 | alarm_config | 120 | enabled | true |
| 1492 | alarm_config | 120 | severity | info |
| 1493 | alarm_config | 120 | serviceAffecting | false |
| 1494 | alarm_config | 120 | extNumber | 8.0000.06 |
| 1495 | alarm_config | 120 | conditionType | DRYCONTACT-IN1 |
| 1496 | alarm_config | 120 | amoType | ENV.DRYCONTACT-IN1 |
| 1497 | alarm_config | 120 | on | 0 |
| 1498 | alarm_config | 121 | id | 121 |
| 1499 | alarm_config | 121 | number | 8000007 |
| 1500 | alarm_config | 121 | description | Input 2 Active |
| 1501 | alarm_config | 121 | enabled | true |
| 1502 | alarm_config | 121 | severity | info |
| 1503 | alarm_config | 121 | serviceAffecting | false |
| 1504 | alarm_config | 121 | extNumber | 8.0000.07 |
| 1505 | alarm_config | 121 | conditionType | DRYCONTACT-IN2 |
| 1506 | alarm_config | 121 | amoType | ENV.DRYCONTACT-IN2 |
| 1507 | alarm_config | 121 | on | 0 |
| 1508 | alarm_config | 122 | id | 122 |
| 1509 | alarm_config | 122 | number | 8000080 |
| 1510 | alarm_config | 122 | description | Troubleshooting tool is running |
| 1511 | alarm_config | 122 | enabled | true |
| 1512 | alarm_config | 122 | severity | major |
| 1513 | alarm_config | 122 | serviceAffecting | false |
| 1514 | alarm_config | 122 | extNumber | 8.0000.80 |
| 1515 | alarm_config | 122 | conditionType | TOOL-DIAG-RUNNING |
| 1516 | alarm_config | 122 | amoType | NE |
| 1517 | alarm_config | 122 | on | 0 |
| 1518 | alarm_config | 123 | id | 123 |
| 1519 | alarm_config | 123 | number | 7000101 |
| 1520 | alarm_config | 123 | description | NTP client lost server communication |
| 1521 | alarm_config | 123 | enabled | true |
| 1522 | alarm_config | 123 | severity | major |
| 1523 | alarm_config | 123 | serviceAffecting | false |
| 1524 | alarm_config | 123 | extNumber | 7.0001.01 |
| 1525 | alarm_config | 123 | conditionType | NTP-STATUS |
| 1526 | alarm_config | 123 | amoType | PROTOCOL.NTP |
| 1527 | alarm_config | 123 | on | 0 |
| 1528 | alarm_config | 124 | id | 124 |
| 1529 | alarm_config | 124 | number | 7000102 |
| 1530 | alarm_config | 124 | description | NTP Time-of-day synchronization - May affect one-way delay measurements |
| 1531 | alarm_config | 124 | enabled | true |
| 1532 | alarm_config | 124 | severity | major |
| 1533 | alarm_config | 124 | serviceAffecting | false |
| 1534 | alarm_config | 124 | extNumber | 7.0001.02 |
| 1535 | alarm_config | 124 | conditionType | NTP-LOST-SYNCH |
| 1536 | alarm_config | 124 | amoType | PROTOCOL.NTP |
| 1537 | alarm_config | 124 | on | 0 |
| 1538 | alarm_config | 125 | id | 125 |
| 1539 | alarm_config | 125 | number | 7000106 |
| 1540 | alarm_config | 125 | description | NTP client used interface without timestamp capability |
| 1541 | alarm_config | 125 | enabled | true |
| 1542 | alarm_config | 125 | severity | major |
| 1543 | alarm_config | 125 | serviceAffecting | false |
| 1544 | alarm_config | 125 | extNumber | 7.0001.06 |
| 1545 | alarm_config | 125 | conditionType | NTP-CAPABILITY |
| 1546 | alarm_config | 125 | amoType | PROTOCOL.NTP |
| 1547 | alarm_config | 125 | on | 0 |
| 1548 | alarm_config | 126 | id | 126 |
| 1549 | alarm_config | 126 | number | 7000108 |
| 1550 | alarm_config | 126 | description | Remote NTP server used an interface without timestamp capability |
| 1551 | alarm_config | 126 | enabled | true |
| 1552 | alarm_config | 126 | severity | major |
| 1553 | alarm_config | 126 | serviceAffecting | false |
| 1554 | alarm_config | 126 | extNumber | 7.0001.08 |
| 1555 | alarm_config | 126 | conditionType | NTP-RMT-CAPABILITY |
| 1556 | alarm_config | 126 | amoType | PROTOCOL.NTP |
| 1557 | alarm_config | 126 | on | 0 |
| 1558 | alarm_config | 127 | id | 127 |
| 1559 | alarm_config | 127 | number | 7000104 |
| 1560 | alarm_config | 127 | description | PTP client failure communication with server |
| 1561 | alarm_config | 127 | enabled | true |
| 1562 | alarm_config | 127 | severity | major |
| 1563 | alarm_config | 127 | serviceAffecting | false |
| 1564 | alarm_config | 127 | extNumber | 7.0001.04 |
| 1565 | alarm_config | 127 | conditionType | PTP-STATUS |
| 1566 | alarm_config | 127 | amoType | PROTOCOL.PTP |
| 1567 | alarm_config | 127 | on | 0 |
| 1568 | alarm_config | 128 | id | 128 |
| 1569 | alarm_config | 128 | number | 7000105 |
| 1570 | alarm_config | 128 | description | PTP Time-of-day synchronization - May affect one-way delay measurements |
| 1571 | alarm_config | 128 | enabled | true |
| 1572 | alarm_config | 128 | severity | major |
| 1573 | alarm_config | 128 | serviceAffecting | false |
| 1574 | alarm_config | 128 | extNumber | 7.0001.05 |
| 1575 | alarm_config | 128 | conditionType | PTP-LOST-SYNCH |
| 1576 | alarm_config | 128 | amoType | PROTOCOL.PTP |
| 1577 | alarm_config | 128 | on | 0 |
| 1578 | alarm_config | 129 | id | 129 |
| 1579 | alarm_config | 129 | number | 7000107 |
| 1580 | alarm_config | 129 | description | PTP client used interface without timestamp capability |
| 1581 | alarm_config | 129 | enabled | true |
| 1582 | alarm_config | 129 | severity | major |
| 1583 | alarm_config | 129 | serviceAffecting | false |
| 1584 | alarm_config | 129 | extNumber | 7.0001.07 |
| 1585 | alarm_config | 129 | conditionType | PTP-CAPABILITY |
| 1586 | alarm_config | 129 | amoType | PROTOCOL.PTP |
| 1587 | alarm_config | 129 | on | 0 |
| 1588 | alarm_config | 130 | id | 130 |
| 1589 | alarm_config | 130 | number | 18000101 |
| 1590 | alarm_config | 130 | description | Inventory entries list is almost full |
| 1591 | alarm_config | 130 | enabled | true |
| 1592 | alarm_config | 130 | severity | minor |
| 1593 | alarm_config | 130 | serviceAffecting | false |
| 1594 | alarm_config | 130 | extNumber | 18.0001.01 |
| 1595 | alarm_config | 130 | conditionType | INVENTORY-ALMOST-FULL |
| 1596 | alarm_config | 130 | amoType | INVENTORY |
| 1597 | alarm_config | 130 | on | 0 |
| 1598 | alarm_config | 131 | id | 131 |
| 1599 | alarm_config | 131 | number | 18000102 |
| 1600 | alarm_config | 131 | description | Inventory entries list is full |
| 1601 | alarm_config | 131 | enabled | true |
| 1602 | alarm_config | 131 | severity | major |
| 1603 | alarm_config | 131 | serviceAffecting | false |
| 1604 | alarm_config | 131 | extNumber | 18.0001.02 |
| 1605 | alarm_config | 131 | conditionType | INVENTORY-FULL |
| 1606 | alarm_config | 131 | amoType | INVENTORY |
| 1607 | alarm_config | 131 | on | 0 |
| 1608 | alarm_config | 132 | id | 132 |
| 1609 | alarm_config | 132 | number | 3000101 |
| 1610 | alarm_config | 132 | description | PAA_Site573_VL2216 PAA_CC_ALERT |
| 1611 | alarm_config | 132 | enabled | true |
| 1612 | alarm_config | 132 | severity | minor |
| 1613 | alarm_config | 132 | serviceAffecting | false |
| 1614 | alarm_config | 132 | extNumber | 3.0001.01 |
| 1615 | alarm_config | 132 | conditionType | CONNECT-LOSS |
| 1616 | alarm_config | 132 | amoType | PAA.PAA_Site573_VL2216 |
| 1617 | alarm_config | 132 | on | 0 |
| 1618 | alarm_config | 133 | id | 133 |
| 1619 | alarm_config | 133 | number | 3000102 |
| 1620 | alarm_config | 133 | description | PAA_Site573_VL2216 PAA_PL_ALERT |
| 1621 | alarm_config | 133 | enabled | true |
| 1622 | alarm_config | 133 | severity | minor |
| 1623 | alarm_config | 133 | serviceAffecting | false |
| 1624 | alarm_config | 133 | extNumber | 3.0001.02 |
| 1625 | alarm_config | 133 | conditionType | PKT-LOSS |
| 1626 | alarm_config | 133 | amoType | PAA.PAA_Site573_VL2216 |
| 1627 | alarm_config | 133 | on | 0 |
| 1628 | alarm_config | 134 | id | 134 |
| 1629 | alarm_config | 134 | number | 3000103 |
| 1630 | alarm_config | 134 | description | PAA_Site573_VL2216 PAA_OW_DELAY_ALERT |
| 1631 | alarm_config | 134 | enabled | true |
| 1632 | alarm_config | 134 | severity | minor |
| 1633 | alarm_config | 134 | serviceAffecting | false |
| 1634 | alarm_config | 134 | extNumber | 3.0001.03 |
| 1635 | alarm_config | 134 | conditionType | OW-DELAY |
| 1636 | alarm_config | 134 | amoType | PAA.PAA_Site573_VL2216 |
| 1637 | alarm_config | 134 | on | 0 |
| 1638 | alarm_config | 135 | id | 135 |
| 1639 | alarm_config | 135 | number | 3000104 |
| 1640 | alarm_config | 135 | description | PAA_Site573_VL2216 PAA_OW_AVG_DELAY_ALERT |
| 1641 | alarm_config | 135 | enabled | true |
| 1642 | alarm_config | 135 | severity | minor |
| 1643 | alarm_config | 135 | serviceAffecting | false |
| 1644 | alarm_config | 135 | extNumber | 3.0001.04 |
| 1645 | alarm_config | 135 | conditionType | OW-AVG-DELAY |
| 1646 | alarm_config | 135 | amoType | PAA.PAA_Site573_VL2216 |
| 1647 | alarm_config | 135 | on | 0 |
| 1648 | alarm_config | 136 | id | 136 |
| 1649 | alarm_config | 136 | number | 3000105 |
| 1650 | alarm_config | 136 | description | PAA_Site573_VL2216 PAA_OW_DV_ALERT |
| 1651 | alarm_config | 136 | enabled | true |
| 1652 | alarm_config | 136 | severity | minor |
| 1653 | alarm_config | 136 | serviceAffecting | false |
| 1654 | alarm_config | 136 | extNumber | 3.0001.05 |
| 1655 | alarm_config | 136 | conditionType | OW-DV |
| 1656 | alarm_config | 136 | amoType | PAA.PAA_Site573_VL2216 |
| 1657 | alarm_config | 136 | on | 0 |
| 1658 | alarm_config | 137 | id | 137 |
| 1659 | alarm_config | 137 | number | 3000106 |
| 1660 | alarm_config | 137 | description | PAA_Site573_VL2216 PAA_OW_AVG_DV_ALERT |
| 1661 | alarm_config | 137 | enabled | true |
| 1662 | alarm_config | 137 | severity | minor |
| 1663 | alarm_config | 137 | serviceAffecting | false |
| 1664 | alarm_config | 137 | extNumber | 3.0001.06 |
| 1665 | alarm_config | 137 | conditionType | OW-AVG-DV |
| 1666 | alarm_config | 137 | amoType | PAA.PAA_Site573_VL2216 |
| 1667 | alarm_config | 137 | on | 0 |
| 1668 | alarm_config | 138 | id | 138 |
| 1669 | alarm_config | 138 | number | 3000107 |
| 1670 | alarm_config | 138 | description | PAA_Site573_VL2216 PAA_TW_DELAY_ALERT |
| 1671 | alarm_config | 138 | enabled | true |
| 1672 | alarm_config | 138 | severity | minor |
| 1673 | alarm_config | 138 | serviceAffecting | false |
| 1674 | alarm_config | 138 | extNumber | 3.0001.07 |
| 1675 | alarm_config | 138 | conditionType | TW-DELAY |
| 1676 | alarm_config | 138 | amoType | PAA.PAA_Site573_VL2216 |
| 1677 | alarm_config | 138 | on | 0 |
| 1678 | alarm_config | 139 | id | 139 |
| 1679 | alarm_config | 139 | number | 3000108 |
| 1680 | alarm_config | 139 | description | PAA_Site573_VL2216 PAA_TW_AVG_DELAY_ALERT |
| 1681 | alarm_config | 139 | enabled | true |
| 1682 | alarm_config | 139 | severity | minor |
| 1683 | alarm_config | 139 | serviceAffecting | false |
| 1684 | alarm_config | 139 | extNumber | 3.0001.08 |
| 1685 | alarm_config | 139 | conditionType | TW-AVG-DELAY |
| 1686 | alarm_config | 139 | amoType | PAA.PAA_Site573_VL2216 |
| 1687 | alarm_config | 139 | on | 0 |
| 1688 | alarm_config | 140 | id | 140 |
| 1689 | alarm_config | 140 | number | 3000109 |
| 1690 | alarm_config | 140 | description | PAA_Site573_VL2216 PAA_TW_DV_ALERT |
| 1691 | alarm_config | 140 | enabled | true |
| 1692 | alarm_config | 140 | severity | minor |
| 1693 | alarm_config | 140 | serviceAffecting | false |
| 1694 | alarm_config | 140 | extNumber | 3.0001.09 |
| 1695 | alarm_config | 140 | conditionType | TW-DV |
| 1696 | alarm_config | 140 | amoType | PAA.PAA_Site573_VL2216 |
| 1697 | alarm_config | 140 | on | 0 |
| 1698 | alarm_config | 141 | id | 141 |
| 1699 | alarm_config | 141 | number | 3000110 |
| 1700 | alarm_config | 141 | description | PAA_Site573_VL2216 PAA_TW_AVG_DV_ALERT |
| 1701 | alarm_config | 141 | enabled | true |
| 1702 | alarm_config | 141 | severity | minor |
| 1703 | alarm_config | 141 | serviceAffecting | false |
| 1704 | alarm_config | 141 | extNumber | 3.0001.10 |
| 1705 | alarm_config | 141 | conditionType | TW-AVG-DV |
| 1706 | alarm_config | 141 | amoType | PAA.PAA_Site573_VL2216 |
| 1707 | alarm_config | 141 | on | 0 |
| 1708 | alarm_config | 142 | id | 142 |
| 1709 | alarm_config | 142 | number | 3000111 |
| 1710 | alarm_config | 142 | description | PAA_Site573_VL2216 PAA_VLAN1_ID_ALERT |
| 1711 | alarm_config | 142 | enabled | true |
| 1712 | alarm_config | 142 | severity | minor |
| 1713 | alarm_config | 142 | serviceAffecting | false |
| 1714 | alarm_config | 142 | extNumber | 3.0001.11 |
| 1715 | alarm_config | 142 | conditionType | VLAN1-ID |
| 1716 | alarm_config | 142 | amoType | PAA.PAA_Site573_VL2216 |
| 1717 | alarm_config | 142 | on | 0 |
| 1718 | alarm_config | 143 | id | 143 |
| 1719 | alarm_config | 143 | number | 3000112 |
| 1720 | alarm_config | 143 | description | PAA_Site573_VL2216 PAA_VLAN2_ID_ALERT |
| 1721 | alarm_config | 143 | enabled | true |
| 1722 | alarm_config | 143 | severity | minor |
| 1723 | alarm_config | 143 | serviceAffecting | false |
| 1724 | alarm_config | 143 | extNumber | 3.0001.12 |
| 1725 | alarm_config | 143 | conditionType | VLAN2-ID |
| 1726 | alarm_config | 143 | amoType | PAA.PAA_Site573_VL2216 |
| 1727 | alarm_config | 143 | on | 0 |
| 1728 | alarm_config | 144 | id | 144 |
| 1729 | alarm_config | 144 | number | 3000113 |
| 1730 | alarm_config | 144 | description | PAA_Site573_VL2216 PAA_VLAN1_PRIO_ALERT |
| 1731 | alarm_config | 144 | enabled | true |
| 1732 | alarm_config | 144 | severity | minor |
| 1733 | alarm_config | 144 | serviceAffecting | false |
| 1734 | alarm_config | 144 | extNumber | 3.0001.13 |
| 1735 | alarm_config | 144 | conditionType | VLAN1-PRIO |
| 1736 | alarm_config | 144 | amoType | PAA.PAA_Site573_VL2216 |
| 1737 | alarm_config | 144 | on | 0 |
| 1738 | alarm_config | 145 | id | 145 |
| 1739 | alarm_config | 145 | number | 3000114 |
| 1740 | alarm_config | 145 | description | PAA_Site573_VL2216 PAA_VLAN2_PRIO_ALERT |
| 1741 | alarm_config | 145 | enabled | true |
| 1742 | alarm_config | 145 | severity | minor |
| 1743 | alarm_config | 145 | serviceAffecting | false |
| 1744 | alarm_config | 145 | extNumber | 3.0001.14 |
| 1745 | alarm_config | 145 | conditionType | VLAN2-PRIO |
| 1746 | alarm_config | 145 | amoType | PAA.PAA_Site573_VL2216 |
| 1747 | alarm_config | 145 | on | 0 |
| 1748 | alarm_config | 146 | id | 146 |
| 1749 | alarm_config | 146 | number | 3000115 |
| 1750 | alarm_config | 146 | description | PAA_Site573_VL2216 PAA_DSCP_ALERT |
| 1751 | alarm_config | 146 | enabled | true |
| 1752 | alarm_config | 146 | severity | minor |
| 1753 | alarm_config | 146 | serviceAffecting | false |
| 1754 | alarm_config | 146 | extNumber | 3.0001.15 |
| 1755 | alarm_config | 146 | conditionType | DSCP |
| 1756 | alarm_config | 146 | amoType | PAA.PAA_Site573_VL2216 |
| 1757 | alarm_config | 146 | on | 0 |
| 1758 | alarm_config | 147 | id | 147 |
| 1759 | alarm_config | 147 | number | 3000201 |
| 1760 | alarm_config | 147 | description | PAA_site573_2216_PNAP PAA_CC_ALERT |
| 1761 | alarm_config | 147 | enabled | true |
| 1762 | alarm_config | 147 | severity | minor |
| 1763 | alarm_config | 147 | serviceAffecting | false |
| 1764 | alarm_config | 147 | extNumber | 3.0002.01 |
| 1765 | alarm_config | 147 | conditionType | CONNECT-LOSS |
| 1766 | alarm_config | 147 | amoType | PAA.PAA_site573_2216_PNAP |
| 1767 | alarm_config | 147 | on | 0 |
| 1768 | alarm_config | 148 | id | 148 |
| 1769 | alarm_config | 148 | number | 3000202 |
| 1770 | alarm_config | 148 | description | PAA_site573_2216_PNAP PAA_PL_ALERT |
| 1771 | alarm_config | 148 | enabled | true |
| 1772 | alarm_config | 148 | severity | minor |
| 1773 | alarm_config | 148 | serviceAffecting | false |
| 1774 | alarm_config | 148 | extNumber | 3.0002.02 |
| 1775 | alarm_config | 148 | conditionType | PKT-LOSS |
| 1776 | alarm_config | 148 | amoType | PAA.PAA_site573_2216_PNAP |
| 1777 | alarm_config | 148 | on | 0 |
| 1778 | alarm_config | 149 | id | 149 |
| 1779 | alarm_config | 149 | number | 3000203 |
| 1780 | alarm_config | 149 | description | PAA_site573_2216_PNAP PAA_OW_DELAY_ALERT |
| 1781 | alarm_config | 149 | enabled | true |
| 1782 | alarm_config | 149 | severity | minor |
| 1783 | alarm_config | 149 | serviceAffecting | false |
| 1784 | alarm_config | 149 | extNumber | 3.0002.03 |
| 1785 | alarm_config | 149 | conditionType | OW-DELAY |
| 1786 | alarm_config | 149 | amoType | PAA.PAA_site573_2216_PNAP |
| 1787 | alarm_config | 149 | on | 0 |
| 1788 | alarm_config | 150 | id | 150 |
| 1789 | alarm_config | 150 | number | 3000204 |
| 1790 | alarm_config | 150 | description | PAA_site573_2216_PNAP PAA_OW_AVG_DELAY_ALERT |
| 1791 | alarm_config | 150 | enabled | true |
| 1792 | alarm_config | 150 | severity | minor |
| 1793 | alarm_config | 150 | serviceAffecting | false |
| 1794 | alarm_config | 150 | extNumber | 3.0002.04 |
| 1795 | alarm_config | 150 | conditionType | OW-AVG-DELAY |
| 1796 | alarm_config | 150 | amoType | PAA.PAA_site573_2216_PNAP |
| 1797 | alarm_config | 150 | on | 0 |
| 1798 | alarm_config | 151 | id | 151 |
| 1799 | alarm_config | 151 | number | 3000205 |
| 1800 | alarm_config | 151 | description | PAA_site573_2216_PNAP PAA_OW_DV_ALERT |
| 1801 | alarm_config | 151 | enabled | true |
| 1802 | alarm_config | 151 | severity | minor |
| 1803 | alarm_config | 151 | serviceAffecting | false |
| 1804 | alarm_config | 151 | extNumber | 3.0002.05 |
| 1805 | alarm_config | 151 | conditionType | OW-DV |
| 1806 | alarm_config | 151 | amoType | PAA.PAA_site573_2216_PNAP |
| 1807 | alarm_config | 151 | on | 0 |
| 1808 | alarm_config | 152 | id | 152 |
| 1809 | alarm_config | 152 | number | 3000206 |
| 1810 | alarm_config | 152 | description | PAA_site573_2216_PNAP PAA_OW_AVG_DV_ALERT |
| 1811 | alarm_config | 152 | enabled | true |
| 1812 | alarm_config | 152 | severity | minor |
| 1813 | alarm_config | 152 | serviceAffecting | false |
| 1814 | alarm_config | 152 | extNumber | 3.0002.06 |
| 1815 | alarm_config | 152 | conditionType | OW-AVG-DV |
| 1816 | alarm_config | 152 | amoType | PAA.PAA_site573_2216_PNAP |
| 1817 | alarm_config | 152 | on | 0 |
| 1818 | alarm_config | 153 | id | 153 |
| 1819 | alarm_config | 153 | number | 3000207 |
| 1820 | alarm_config | 153 | description | PAA_site573_2216_PNAP PAA_TW_DELAY_ALERT |
| 1821 | alarm_config | 153 | enabled | true |
| 1822 | alarm_config | 153 | severity | minor |
| 1823 | alarm_config | 153 | serviceAffecting | false |
| 1824 | alarm_config | 153 | extNumber | 3.0002.07 |
| 1825 | alarm_config | 153 | conditionType | TW-DELAY |
| 1826 | alarm_config | 153 | amoType | PAA.PAA_site573_2216_PNAP |
| 1827 | alarm_config | 153 | on | 0 |
| 1828 | alarm_config | 154 | id | 154 |
| 1829 | alarm_config | 154 | number | 3000208 |
| 1830 | alarm_config | 154 | description | PAA_site573_2216_PNAP PAA_TW_AVG_DELAY_ALERT |
| 1831 | alarm_config | 154 | enabled | true |
| 1832 | alarm_config | 154 | severity | minor |
| 1833 | alarm_config | 154 | serviceAffecting | false |
| 1834 | alarm_config | 154 | extNumber | 3.0002.08 |
| 1835 | alarm_config | 154 | conditionType | TW-AVG-DELAY |
| 1836 | alarm_config | 154 | amoType | PAA.PAA_site573_2216_PNAP |
| 1837 | alarm_config | 154 | on | 0 |
| 1838 | alarm_config | 155 | id | 155 |
| 1839 | alarm_config | 155 | number | 3000209 |
| 1840 | alarm_config | 155 | description | PAA_site573_2216_PNAP PAA_TW_DV_ALERT |
| 1841 | alarm_config | 155 | enabled | true |
| 1842 | alarm_config | 155 | severity | minor |
| 1843 | alarm_config | 155 | serviceAffecting | false |
| 1844 | alarm_config | 155 | extNumber | 3.0002.09 |
| 1845 | alarm_config | 155 | conditionType | TW-DV |
| 1846 | alarm_config | 155 | amoType | PAA.PAA_site573_2216_PNAP |
| 1847 | alarm_config | 155 | on | 0 |
| 1848 | alarm_config | 156 | id | 156 |
| 1849 | alarm_config | 156 | number | 3000210 |
| 1850 | alarm_config | 156 | description | PAA_site573_2216_PNAP PAA_TW_AVG_DV_ALERT |
| 1851 | alarm_config | 156 | enabled | true |
| 1852 | alarm_config | 156 | severity | minor |
| 1853 | alarm_config | 156 | serviceAffecting | false |
| 1854 | alarm_config | 156 | extNumber | 3.0002.10 |
| 1855 | alarm_config | 156 | conditionType | TW-AVG-DV |
| 1856 | alarm_config | 156 | amoType | PAA.PAA_site573_2216_PNAP |
| 1857 | alarm_config | 156 | on | 0 |
| 1858 | alarm_config | 157 | id | 157 |
| 1859 | alarm_config | 157 | number | 3000211 |
| 1860 | alarm_config | 157 | description | PAA_site573_2216_PNAP PAA_VLAN1_ID_ALERT |
| 1861 | alarm_config | 157 | enabled | true |
| 1862 | alarm_config | 157 | severity | minor |
| 1863 | alarm_config | 157 | serviceAffecting | false |
| 1864 | alarm_config | 157 | extNumber | 3.0002.11 |
| 1865 | alarm_config | 157 | conditionType | VLAN1-ID |
| 1866 | alarm_config | 157 | amoType | PAA.PAA_site573_2216_PNAP |
| 1867 | alarm_config | 157 | on | 0 |
| 1868 | alarm_config | 158 | id | 158 |
| 1869 | alarm_config | 158 | number | 3000212 |
| 1870 | alarm_config | 158 | description | PAA_site573_2216_PNAP PAA_VLAN2_ID_ALERT |
| 1871 | alarm_config | 158 | enabled | true |
| 1872 | alarm_config | 158 | severity | minor |
| 1873 | alarm_config | 158 | serviceAffecting | false |
| 1874 | alarm_config | 158 | extNumber | 3.0002.12 |
| 1875 | alarm_config | 158 | conditionType | VLAN2-ID |
| 1876 | alarm_config | 158 | amoType | PAA.PAA_site573_2216_PNAP |
| 1877 | alarm_config | 158 | on | 0 |
| 1878 | alarm_config | 159 | id | 159 |
| 1879 | alarm_config | 159 | number | 3000213 |
| 1880 | alarm_config | 159 | description | PAA_site573_2216_PNAP PAA_VLAN1_PRIO_ALERT |
| 1881 | alarm_config | 159 | enabled | true |
| 1882 | alarm_config | 159 | severity | minor |
| 1883 | alarm_config | 159 | serviceAffecting | false |
| 1884 | alarm_config | 159 | extNumber | 3.0002.13 |
| 1885 | alarm_config | 159 | conditionType | VLAN1-PRIO |
| 1886 | alarm_config | 159 | amoType | PAA.PAA_site573_2216_PNAP |
| 1887 | alarm_config | 159 | on | 0 |
| 1888 | alarm_config | 160 | id | 160 |
| 1889 | alarm_config | 160 | number | 3000214 |
| 1890 | alarm_config | 160 | description | PAA_site573_2216_PNAP PAA_VLAN2_PRIO_ALERT |
| 1891 | alarm_config | 160 | enabled | true |
| 1892 | alarm_config | 160 | severity | minor |
| 1893 | alarm_config | 160 | serviceAffecting | false |
| 1894 | alarm_config | 160 | extNumber | 3.0002.14 |
| 1895 | alarm_config | 160 | conditionType | VLAN2-PRIO |
| 1896 | alarm_config | 160 | amoType | PAA.PAA_site573_2216_PNAP |
| 1897 | alarm_config | 160 | on | 0 |
| 1898 | alarm_config | 161 | id | 161 |
| 1899 | alarm_config | 161 | number | 3000215 |
| 1900 | alarm_config | 161 | description | PAA_site573_2216_PNAP PAA_DSCP_ALERT |
| 1901 | alarm_config | 161 | enabled | true |
| 1902 | alarm_config | 161 | severity | minor |
| 1903 | alarm_config | 161 | serviceAffecting | false |
| 1904 | alarm_config | 161 | extNumber | 3.0002.15 |
| 1905 | alarm_config | 161 | conditionType | DSCP |
| 1906 | alarm_config | 161 | amoType | PAA.PAA_site573_2216_PNAP |
| 1907 | alarm_config | 161 | on | 0 |
| 1908 | alarm_config | 162 | id | 162 |
| 1909 | alarm_config | 162 | number | 3000301 |
| 1910 | alarm_config | 162 | description | PAA_Site573_VL2217 PAA_CC_ALERT |
| 1911 | alarm_config | 162 | enabled | true |
| 1912 | alarm_config | 162 | severity | minor |
| 1913 | alarm_config | 162 | serviceAffecting | false |
| 1914 | alarm_config | 162 | extNumber | 3.0003.01 |
| 1915 | alarm_config | 162 | conditionType | CONNECT-LOSS |
| 1916 | alarm_config | 162 | amoType | PAA.PAA_Site573_VL2217 |
| 1917 | alarm_config | 162 | on | 0 |
| 1918 | alarm_config | 163 | id | 163 |
| 1919 | alarm_config | 163 | number | 3000302 |
| 1920 | alarm_config | 163 | description | PAA_Site573_VL2217 PAA_PL_ALERT |
| 1921 | alarm_config | 163 | enabled | true |
| 1922 | alarm_config | 163 | severity | minor |
| 1923 | alarm_config | 163 | serviceAffecting | false |
| 1924 | alarm_config | 163 | extNumber | 3.0003.02 |
| 1925 | alarm_config | 163 | conditionType | PKT-LOSS |
| 1926 | alarm_config | 163 | amoType | PAA.PAA_Site573_VL2217 |
| 1927 | alarm_config | 163 | on | 0 |
| 1928 | alarm_config | 164 | id | 164 |
| 1929 | alarm_config | 164 | number | 3000303 |
| 1930 | alarm_config | 164 | description | PAA_Site573_VL2217 PAA_OW_DELAY_ALERT |
| 1931 | alarm_config | 164 | enabled | true |
| 1932 | alarm_config | 164 | severity | minor |
| 1933 | alarm_config | 164 | serviceAffecting | false |
| 1934 | alarm_config | 164 | extNumber | 3.0003.03 |
| 1935 | alarm_config | 164 | conditionType | OW-DELAY |
| 1936 | alarm_config | 164 | amoType | PAA.PAA_Site573_VL2217 |
| 1937 | alarm_config | 164 | on | 0 |
| 1938 | alarm_config | 165 | id | 165 |
| 1939 | alarm_config | 165 | number | 3000304 |
| 1940 | alarm_config | 165 | description | PAA_Site573_VL2217 PAA_OW_AVG_DELAY_ALERT |
| 1941 | alarm_config | 165 | enabled | true |
| 1942 | alarm_config | 165 | severity | minor |
| 1943 | alarm_config | 165 | serviceAffecting | false |
| 1944 | alarm_config | 165 | extNumber | 3.0003.04 |
| 1945 | alarm_config | 165 | conditionType | OW-AVG-DELAY |
| 1946 | alarm_config | 165 | amoType | PAA.PAA_Site573_VL2217 |
| 1947 | alarm_config | 165 | on | 0 |
| 1948 | alarm_config | 166 | id | 166 |
| 1949 | alarm_config | 166 | number | 3000305 |
| 1950 | alarm_config | 166 | description | PAA_Site573_VL2217 PAA_OW_DV_ALERT |
| 1951 | alarm_config | 166 | enabled | true |
| 1952 | alarm_config | 166 | severity | minor |
| 1953 | alarm_config | 166 | serviceAffecting | false |
| 1954 | alarm_config | 166 | extNumber | 3.0003.05 |
| 1955 | alarm_config | 166 | conditionType | OW-DV |
| 1956 | alarm_config | 166 | amoType | PAA.PAA_Site573_VL2217 |
| 1957 | alarm_config | 166 | on | 0 |
| 1958 | alarm_config | 167 | id | 167 |
| 1959 | alarm_config | 167 | number | 3000306 |
| 1960 | alarm_config | 167 | description | PAA_Site573_VL2217 PAA_OW_AVG_DV_ALERT |
| 1961 | alarm_config | 167 | enabled | true |
| 1962 | alarm_config | 167 | severity | minor |
| 1963 | alarm_config | 167 | serviceAffecting | false |
| 1964 | alarm_config | 167 | extNumber | 3.0003.06 |
| 1965 | alarm_config | 167 | conditionType | OW-AVG-DV |
| 1966 | alarm_config | 167 | amoType | PAA.PAA_Site573_VL2217 |
| 1967 | alarm_config | 167 | on | 0 |
| 1968 | alarm_config | 168 | id | 168 |
| 1969 | alarm_config | 168 | number | 3000307 |
| 1970 | alarm_config | 168 | description | PAA_Site573_VL2217 PAA_TW_DELAY_ALERT |
| 1971 | alarm_config | 168 | enabled | true |
| 1972 | alarm_config | 168 | severity | minor |
| 1973 | alarm_config | 168 | serviceAffecting | false |
| 1974 | alarm_config | 168 | extNumber | 3.0003.07 |
| 1975 | alarm_config | 168 | conditionType | TW-DELAY |
| 1976 | alarm_config | 168 | amoType | PAA.PAA_Site573_VL2217 |
| 1977 | alarm_config | 168 | on | 0 |
| 1978 | alarm_config | 169 | id | 169 |
| 1979 | alarm_config | 169 | number | 3000308 |
| 1980 | alarm_config | 169 | description | PAA_Site573_VL2217 PAA_TW_AVG_DELAY_ALERT |
| 1981 | alarm_config | 169 | enabled | true |
| 1982 | alarm_config | 169 | severity | minor |
| 1983 | alarm_config | 169 | serviceAffecting | false |
| 1984 | alarm_config | 169 | extNumber | 3.0003.08 |
| 1985 | alarm_config | 169 | conditionType | TW-AVG-DELAY |
| 1986 | alarm_config | 169 | amoType | PAA.PAA_Site573_VL2217 |
| 1987 | alarm_config | 169 | on | 0 |
| 1988 | alarm_config | 170 | id | 170 |
| 1989 | alarm_config | 170 | number | 3000309 |
| 1990 | alarm_config | 170 | description | PAA_Site573_VL2217 PAA_TW_DV_ALERT |
| 1991 | alarm_config | 170 | enabled | true |
| 1992 | alarm_config | 170 | severity | minor |
| 1993 | alarm_config | 170 | serviceAffecting | false |
| 1994 | alarm_config | 170 | extNumber | 3.0003.09 |
| 1995 | alarm_config | 170 | conditionType | TW-DV |
| 1996 | alarm_config | 170 | amoType | PAA.PAA_Site573_VL2217 |
| 1997 | alarm_config | 170 | on | 0 |
| 1998 | alarm_config | 171 | id | 171 |
| 1999 | alarm_config | 171 | number | 3000310 |
| 2000 | alarm_config | 171 | description | PAA_Site573_VL2217 PAA_TW_AVG_DV_ALERT |
| 2001 | alarm_config | 171 | enabled | true |
| 2002 | alarm_config | 171 | severity | minor |
| 2003 | alarm_config | 171 | serviceAffecting | false |
| 2004 | alarm_config | 171 | extNumber | 3.0003.10 |
| 2005 | alarm_config | 171 | conditionType | TW-AVG-DV |
| 2006 | alarm_config | 171 | amoType | PAA.PAA_Site573_VL2217 |
| 2007 | alarm_config | 171 | on | 0 |
| 2008 | alarm_config | 172 | id | 172 |
| 2009 | alarm_config | 172 | number | 3000311 |
| 2010 | alarm_config | 172 | description | PAA_Site573_VL2217 PAA_VLAN1_ID_ALERT |
| 2011 | alarm_config | 172 | enabled | true |
| 2012 | alarm_config | 172 | severity | minor |
| 2013 | alarm_config | 172 | serviceAffecting | false |
| 2014 | alarm_config | 172 | extNumber | 3.0003.11 |
| 2015 | alarm_config | 172 | conditionType | VLAN1-ID |
| 2016 | alarm_config | 172 | amoType | PAA.PAA_Site573_VL2217 |
| 2017 | alarm_config | 172 | on | 0 |
| 2018 | alarm_config | 173 | id | 173 |
| 2019 | alarm_config | 173 | number | 3000312 |
| 2020 | alarm_config | 173 | description | PAA_Site573_VL2217 PAA_VLAN2_ID_ALERT |
| 2021 | alarm_config | 173 | enabled | true |
| 2022 | alarm_config | 173 | severity | minor |
| 2023 | alarm_config | 173 | serviceAffecting | false |
| 2024 | alarm_config | 173 | extNumber | 3.0003.12 |
| 2025 | alarm_config | 173 | conditionType | VLAN2-ID |
| 2026 | alarm_config | 173 | amoType | PAA.PAA_Site573_VL2217 |
| 2027 | alarm_config | 173 | on | 0 |
| 2028 | alarm_config | 174 | id | 174 |
| 2029 | alarm_config | 174 | number | 3000313 |
| 2030 | alarm_config | 174 | description | PAA_Site573_VL2217 PAA_VLAN1_PRIO_ALERT |
| 2031 | alarm_config | 174 | enabled | true |
| 2032 | alarm_config | 174 | severity | minor |
| 2033 | alarm_config | 174 | serviceAffecting | false |
| 2034 | alarm_config | 174 | extNumber | 3.0003.13 |
| 2035 | alarm_config | 174 | conditionType | VLAN1-PRIO |
| 2036 | alarm_config | 174 | amoType | PAA.PAA_Site573_VL2217 |
| 2037 | alarm_config | 174 | on | 0 |
| 2038 | alarm_config | 175 | id | 175 |
| 2039 | alarm_config | 175 | number | 3000314 |
| 2040 | alarm_config | 175 | description | PAA_Site573_VL2217 PAA_VLAN2_PRIO_ALERT |
| 2041 | alarm_config | 175 | enabled | true |
| 2042 | alarm_config | 175 | severity | minor |
| 2043 | alarm_config | 175 | serviceAffecting | false |
| 2044 | alarm_config | 175 | extNumber | 3.0003.14 |
| 2045 | alarm_config | 175 | conditionType | VLAN2-PRIO |
| 2046 | alarm_config | 175 | amoType | PAA.PAA_Site573_VL2217 |
| 2047 | alarm_config | 175 | on | 0 |
| 2048 | alarm_config | 176 | id | 176 |
| 2049 | alarm_config | 176 | number | 3000315 |
| 2050 | alarm_config | 176 | description | PAA_Site573_VL2217 PAA_DSCP_ALERT |
| 2051 | alarm_config | 176 | enabled | true |
| 2052 | alarm_config | 176 | severity | minor |
| 2053 | alarm_config | 176 | serviceAffecting | false |
| 2054 | alarm_config | 176 | extNumber | 3.0003.15 |
| 2055 | alarm_config | 176 | conditionType | DSCP |
| 2056 | alarm_config | 176 | amoType | PAA.PAA_Site573_VL2217 |
| 2057 | alarm_config | 176 | on | 0 |
| 2058 | alarm_config | 177 | id | 177 |
| 2059 | alarm_config | 177 | number | 3000401 |
| 2060 | alarm_config | 177 | description | PAA_site573_2217_PNAP PAA_CC_ALERT |
| 2061 | alarm_config | 177 | enabled | true |
| 2062 | alarm_config | 177 | severity | minor |
| 2063 | alarm_config | 177 | serviceAffecting | false |
| 2064 | alarm_config | 177 | extNumber | 3.0004.01 |
| 2065 | alarm_config | 177 | conditionType | CONNECT-LOSS |
| 2066 | alarm_config | 177 | amoType | PAA.PAA_site573_2217_PNAP |
| 2067 | alarm_config | 177 | on | 0 |
| 2068 | alarm_config | 178 | id | 178 |
| 2069 | alarm_config | 178 | number | 3000402 |
| 2070 | alarm_config | 178 | description | PAA_site573_2217_PNAP PAA_PL_ALERT |
| 2071 | alarm_config | 178 | enabled | true |
| 2072 | alarm_config | 178 | severity | minor |
| 2073 | alarm_config | 178 | serviceAffecting | false |
| 2074 | alarm_config | 178 | extNumber | 3.0004.02 |
| 2075 | alarm_config | 178 | conditionType | PKT-LOSS |
| 2076 | alarm_config | 178 | amoType | PAA.PAA_site573_2217_PNAP |
| 2077 | alarm_config | 178 | on | 0 |
| 2078 | alarm_config | 179 | id | 179 |
| 2079 | alarm_config | 179 | number | 3000403 |
| 2080 | alarm_config | 179 | description | PAA_site573_2217_PNAP PAA_OW_DELAY_ALERT |
| 2081 | alarm_config | 179 | enabled | true |
| 2082 | alarm_config | 179 | severity | minor |
| 2083 | alarm_config | 179 | serviceAffecting | false |
| 2084 | alarm_config | 179 | extNumber | 3.0004.03 |
| 2085 | alarm_config | 179 | conditionType | OW-DELAY |
| 2086 | alarm_config | 179 | amoType | PAA.PAA_site573_2217_PNAP |
| 2087 | alarm_config | 179 | on | 0 |
| 2088 | alarm_config | 180 | id | 180 |
| 2089 | alarm_config | 180 | number | 3000404 |
| 2090 | alarm_config | 180 | description | PAA_site573_2217_PNAP PAA_OW_AVG_DELAY_ALERT |
| 2091 | alarm_config | 180 | enabled | true |
| 2092 | alarm_config | 180 | severity | minor |
| 2093 | alarm_config | 180 | serviceAffecting | false |
| 2094 | alarm_config | 180 | extNumber | 3.0004.04 |
| 2095 | alarm_config | 180 | conditionType | OW-AVG-DELAY |
| 2096 | alarm_config | 180 | amoType | PAA.PAA_site573_2217_PNAP |
| 2097 | alarm_config | 180 | on | 0 |
| 2098 | alarm_config | 181 | id | 181 |
| 2099 | alarm_config | 181 | number | 3000405 |
| 2100 | alarm_config | 181 | description | PAA_site573_2217_PNAP PAA_OW_DV_ALERT |
| 2101 | alarm_config | 181 | enabled | true |
| 2102 | alarm_config | 181 | severity | minor |
| 2103 | alarm_config | 181 | serviceAffecting | false |
| 2104 | alarm_config | 181 | extNumber | 3.0004.05 |
| 2105 | alarm_config | 181 | conditionType | OW-DV |
| 2106 | alarm_config | 181 | amoType | PAA.PAA_site573_2217_PNAP |
| 2107 | alarm_config | 181 | on | 0 |
| 2108 | alarm_config | 182 | id | 182 |
| 2109 | alarm_config | 182 | number | 3000406 |
| 2110 | alarm_config | 182 | description | PAA_site573_2217_PNAP PAA_OW_AVG_DV_ALERT |
| 2111 | alarm_config | 182 | enabled | true |
| 2112 | alarm_config | 182 | severity | minor |
| 2113 | alarm_config | 182 | serviceAffecting | false |
| 2114 | alarm_config | 182 | extNumber | 3.0004.06 |
| 2115 | alarm_config | 182 | conditionType | OW-AVG-DV |
| 2116 | alarm_config | 182 | amoType | PAA.PAA_site573_2217_PNAP |
| 2117 | alarm_config | 182 | on | 0 |
| 2118 | alarm_config | 183 | id | 183 |
| 2119 | alarm_config | 183 | number | 3000407 |
| 2120 | alarm_config | 183 | description | PAA_site573_2217_PNAP PAA_TW_DELAY_ALERT |
| 2121 | alarm_config | 183 | enabled | true |
| 2122 | alarm_config | 183 | severity | minor |
| 2123 | alarm_config | 183 | serviceAffecting | false |
| 2124 | alarm_config | 183 | extNumber | 3.0004.07 |
| 2125 | alarm_config | 183 | conditionType | TW-DELAY |
| 2126 | alarm_config | 183 | amoType | PAA.PAA_site573_2217_PNAP |
| 2127 | alarm_config | 183 | on | 0 |
| 2128 | alarm_config | 184 | id | 184 |
| 2129 | alarm_config | 184 | number | 3000408 |
| 2130 | alarm_config | 184 | description | PAA_site573_2217_PNAP PAA_TW_AVG_DELAY_ALERT |
| 2131 | alarm_config | 184 | enabled | true |
| 2132 | alarm_config | 184 | severity | minor |
| 2133 | alarm_config | 184 | serviceAffecting | false |
| 2134 | alarm_config | 184 | extNumber | 3.0004.08 |
| 2135 | alarm_config | 184 | conditionType | TW-AVG-DELAY |
| 2136 | alarm_config | 184 | amoType | PAA.PAA_site573_2217_PNAP |
| 2137 | alarm_config | 184 | on | 0 |
| 2138 | alarm_config | 185 | id | 185 |
| 2139 | alarm_config | 185 | number | 3000409 |
| 2140 | alarm_config | 185 | description | PAA_site573_2217_PNAP PAA_TW_DV_ALERT |
| 2141 | alarm_config | 185 | enabled | true |
| 2142 | alarm_config | 185 | severity | minor |
| 2143 | alarm_config | 185 | serviceAffecting | false |
| 2144 | alarm_config | 185 | extNumber | 3.0004.09 |
| 2145 | alarm_config | 185 | conditionType | TW-DV |
| 2146 | alarm_config | 185 | amoType | PAA.PAA_site573_2217_PNAP |
| 2147 | alarm_config | 185 | on | 0 |
| 2148 | alarm_config | 186 | id | 186 |
| 2149 | alarm_config | 186 | number | 3000410 |
| 2150 | alarm_config | 186 | description | PAA_site573_2217_PNAP PAA_TW_AVG_DV_ALERT |
| 2151 | alarm_config | 186 | enabled | true |
| 2152 | alarm_config | 186 | severity | minor |
| 2153 | alarm_config | 186 | serviceAffecting | false |
| 2154 | alarm_config | 186 | extNumber | 3.0004.10 |
| 2155 | alarm_config | 186 | conditionType | TW-AVG-DV |
| 2156 | alarm_config | 186 | amoType | PAA.PAA_site573_2217_PNAP |
| 2157 | alarm_config | 186 | on | 0 |
| 2158 | alarm_config | 187 | id | 187 |
| 2159 | alarm_config | 187 | number | 3000411 |
| 2160 | alarm_config | 187 | description | PAA_site573_2217_PNAP PAA_VLAN1_ID_ALERT |
| 2161 | alarm_config | 187 | enabled | true |
| 2162 | alarm_config | 187 | severity | minor |
| 2163 | alarm_config | 187 | serviceAffecting | false |
| 2164 | alarm_config | 187 | extNumber | 3.0004.11 |
| 2165 | alarm_config | 187 | conditionType | VLAN1-ID |
| 2166 | alarm_config | 187 | amoType | PAA.PAA_site573_2217_PNAP |
| 2167 | alarm_config | 187 | on | 0 |
| 2168 | alarm_config | 188 | id | 188 |
| 2169 | alarm_config | 188 | number | 3000412 |
| 2170 | alarm_config | 188 | description | PAA_site573_2217_PNAP PAA_VLAN2_ID_ALERT |
| 2171 | alarm_config | 188 | enabled | true |
| 2172 | alarm_config | 188 | severity | minor |
| 2173 | alarm_config | 188 | serviceAffecting | false |
| 2174 | alarm_config | 188 | extNumber | 3.0004.12 |
| 2175 | alarm_config | 188 | conditionType | VLAN2-ID |
| 2176 | alarm_config | 188 | amoType | PAA.PAA_site573_2217_PNAP |
| 2177 | alarm_config | 188 | on | 0 |
| 2178 | alarm_config | 189 | id | 189 |
| 2179 | alarm_config | 189 | number | 3000413 |
| 2180 | alarm_config | 189 | description | PAA_site573_2217_PNAP PAA_VLAN1_PRIO_ALERT |
| 2181 | alarm_config | 189 | enabled | true |
| 2182 | alarm_config | 189 | severity | minor |
| 2183 | alarm_config | 189 | serviceAffecting | false |
| 2184 | alarm_config | 189 | extNumber | 3.0004.13 |
| 2185 | alarm_config | 189 | conditionType | VLAN1-PRIO |
| 2186 | alarm_config | 189 | amoType | PAA.PAA_site573_2217_PNAP |
| 2187 | alarm_config | 189 | on | 0 |
| 2188 | alarm_config | 190 | id | 190 |
| 2189 | alarm_config | 190 | number | 3000414 |
| 2190 | alarm_config | 190 | description | PAA_site573_2217_PNAP PAA_VLAN2_PRIO_ALERT |
| 2191 | alarm_config | 190 | enabled | true |
| 2192 | alarm_config | 190 | severity | minor |
| 2193 | alarm_config | 190 | serviceAffecting | false |
| 2194 | alarm_config | 190 | extNumber | 3.0004.14 |
| 2195 | alarm_config | 190 | conditionType | VLAN2-PRIO |
| 2196 | alarm_config | 190 | amoType | PAA.PAA_site573_2217_PNAP |
| 2197 | alarm_config | 190 | on | 0 |
| 2198 | alarm_config | 191 | id | 191 |
| 2199 | alarm_config | 191 | number | 3000415 |
| 2200 | alarm_config | 191 | description | PAA_site573_2217_PNAP PAA_DSCP_ALERT |
| 2201 | alarm_config | 191 | enabled | true |
| 2202 | alarm_config | 191 | severity | minor |
| 2203 | alarm_config | 191 | serviceAffecting | false |
| 2204 | alarm_config | 191 | extNumber | 3.0004.15 |
| 2205 | alarm_config | 191 | conditionType | DSCP |
| 2206 | alarm_config | 191 | amoType | PAA.PAA_site573_2217_PNAP |
| 2207 | alarm_config | 191 | on | 0 |
| 2208 | alarm_config | 192 | id | 192 |
| 2209 | alarm_config | 192 | number | 7000401 |
| 2210 | alarm_config | 192 | description | VCAgent communication failure with Vision EMS |
| 2211 | alarm_config | 192 | enabled | true |
| 2212 | alarm_config | 192 | severity | major |
| 2213 | alarm_config | 192 | serviceAffecting | false |
| 2214 | alarm_config | 192 | extNumber | 7.0004.01 |
| 2215 | alarm_config | 192 | conditionType | VCA-LOST-COMM |
| 2216 | alarm_config | 192 | amoType | VCAGENT |
| 2217 | alarm_config | 192 | on | 0 |
| 2218 | alarm_config | 193 | id | 193 |
| 2219 | alarm_config | 193 | number | 7000412 |
| 2220 | alarm_config | 193 | description | VCAgent High Resolution PAA statistics buffer full |
| 2221 | alarm_config | 193 | enabled | true |
| 2222 | alarm_config | 193 | severity | major |
| 2223 | alarm_config | 193 | serviceAffecting | false |
| 2224 | alarm_config | 193 | extNumber | 7.0004.12 |
| 2225 | alarm_config | 193 | conditionType | VCA-FULL-PAA |
| 2226 | alarm_config | 193 | amoType | VCAGENT |
| 2227 | alarm_config | 193 | on | 0 |
| 2228 | alarm_config | 194 | id | 194 |
| 2229 | alarm_config | 194 | number | 7000404 |
| 2230 | alarm_config | 194 | description | VCAgent High Resolution PAA instances validation |
| 2231 | alarm_config | 194 | enabled | true |
| 2232 | alarm_config | 194 | severity | minor |
| 2233 | alarm_config | 194 | serviceAffecting | false |
| 2234 | alarm_config | 194 | extNumber | 7.0004.04 |
| 2235 | alarm_config | 194 | conditionType | VCA-MAX-PAA |
| 2236 | alarm_config | 194 | amoType | VCAGENT |
| 2237 | alarm_config | 194 | on | 0 |
| 2238 | alarm_config | 195 | id | 195 |
| 2239 | alarm_config | 195 | number | 7000411 |
| 2240 | alarm_config | 195 | description | VCAgent High Resolution Regulator statistics buffer full |
| 2241 | alarm_config | 195 | enabled | true |
| 2242 | alarm_config | 195 | severity | major |
| 2243 | alarm_config | 195 | serviceAffecting | false |
| 2244 | alarm_config | 195 | extNumber | 7.0004.11 |
| 2245 | alarm_config | 195 | conditionType | VCA-FULL-BWP |
| 2246 | alarm_config | 195 | amoType | VCAGENT |
| 2247 | alarm_config | 195 | on | 0 |
| 2248 | alarm_config | 196 | id | 196 |
| 2249 | alarm_config | 196 | number | 7000403 |
| 2250 | alarm_config | 196 | description | VCAgent High Resolution Regulator instances validation |
| 2251 | alarm_config | 196 | enabled | true |
| 2252 | alarm_config | 196 | severity | minor |
| 2253 | alarm_config | 196 | serviceAffecting | false |
| 2254 | alarm_config | 196 | extNumber | 7.0004.03 |
| 2255 | alarm_config | 196 | conditionType | VCA-MAX-BWP |
| 2256 | alarm_config | 196 | amoType | VCAGENT |
| 2257 | alarm_config | 196 | on | 0 |
| 2258 | alarm_config | 197 | id | 197 |
| 2259 | alarm_config | 197 | number | 7000410 |
| 2260 | alarm_config | 197 | description | VCAgent High Resolution Policy statistics buffer full |
| 2261 | alarm_config | 197 | enabled | true |
| 2262 | alarm_config | 197 | severity | major |
| 2263 | alarm_config | 197 | serviceAffecting | false |
| 2264 | alarm_config | 197 | extNumber | 7.0004.10 |
| 2265 | alarm_config | 197 | conditionType | VCA-FULL-POL |
| 2266 | alarm_config | 197 | amoType | VCAGENT |
| 2267 | alarm_config | 197 | on | 0 |
| 2268 | alarm_config | 198 | id | 198 |
| 2269 | alarm_config | 198 | number | 7000402 |
| 2270 | alarm_config | 198 | description | VCAgent High Resolution Policy instances validation |
| 2271 | alarm_config | 198 | enabled | true |
| 2272 | alarm_config | 198 | severity | minor |
| 2273 | alarm_config | 198 | serviceAffecting | false |
| 2274 | alarm_config | 198 | extNumber | 7.0004.02 |
| 2275 | alarm_config | 198 | conditionType | VCA-MAX-POL |
| 2276 | alarm_config | 198 | amoType | VCAGENT |
| 2277 | alarm_config | 198 | on | 0 |
| 2278 | alarm_config | 199 | id | 199 |
| 2279 | alarm_config | 199 | number | 7000414 |
| 2280 | alarm_config | 199 | description | VCAgent High Resolution SOAM DMM statistics buffer full |
| 2281 | alarm_config | 199 | enabled | true |
| 2282 | alarm_config | 199 | severity | major |
| 2283 | alarm_config | 199 | serviceAffecting | false |
| 2284 | alarm_config | 199 | extNumber | 7.0004.14 |
| 2285 | alarm_config | 199 | conditionType | VCA-FULL-DMM |
| 2286 | alarm_config | 199 | amoType | VCAGENT |
| 2287 | alarm_config | 199 | on | 0 |
| 2288 | alarm_config | 200 | id | 200 |
| 2289 | alarm_config | 200 | number | 7000406 |
| 2290 | alarm_config | 200 | description | VCAgent High Resolution SOAM DMM instances validation |
| 2291 | alarm_config | 200 | enabled | true |
| 2292 | alarm_config | 200 | severity | minor |
| 2293 | alarm_config | 200 | serviceAffecting | false |
| 2294 | alarm_config | 200 | extNumber | 7.0004.06 |
| 2295 | alarm_config | 200 | conditionType | VCA-MAX-DMM |
| 2296 | alarm_config | 200 | amoType | VCAGENT |
| 2297 | alarm_config | 200 | on | 0 |
| 2298 | alarm_config | 201 | id | 201 |
| 2299 | alarm_config | 201 | number | 7000413 |
| 2300 | alarm_config | 201 | description | VCAgent High Resolution SOAM PL statistics buffer full |
| 2301 | alarm_config | 201 | enabled | true |
| 2302 | alarm_config | 201 | severity | major |
| 2303 | alarm_config | 201 | serviceAffecting | false |
| 2304 | alarm_config | 201 | extNumber | 7.0004.13 |
| 2305 | alarm_config | 201 | conditionType | VCA-FULL-PL |
| 2306 | alarm_config | 201 | amoType | VCAGENT |
| 2307 | alarm_config | 201 | on | 0 |
| 2308 | alarm_config | 202 | id | 202 |
| 2309 | alarm_config | 202 | number | 7000405 |
| 2310 | alarm_config | 202 | description | VCAgent High Resolution SOAM PL instances validation |
| 2311 | alarm_config | 202 | enabled | true |
| 2312 | alarm_config | 202 | severity | minor |
| 2313 | alarm_config | 202 | serviceAffecting | false |
| 2314 | alarm_config | 202 | extNumber | 7.0004.05 |
| 2315 | alarm_config | 202 | conditionType | VCA-MAX-PL |
| 2316 | alarm_config | 202 | amoType | VCAGENT |
| 2317 | alarm_config | 202 | on | 0 |
| 2318 | alarm_config | 203 | id | 203 |
| 2319 | alarm_config | 203 | number | 7000417 |
| 2320 | alarm_config | 203 | description | VCAgent High Resolution SOAM SLM statistics buffer full |
| 2321 | alarm_config | 203 | enabled | true |
| 2322 | alarm_config | 203 | severity | major |
| 2323 | alarm_config | 203 | serviceAffecting | false |
| 2324 | alarm_config | 203 | extNumber | 7.0004.17 |
| 2325 | alarm_config | 203 | conditionType | VCA-FULL-SLM |
| 2326 | alarm_config | 203 | amoType | VCAGENT |
| 2327 | alarm_config | 203 | on | 0 |
| 2328 | alarm_config | 204 | id | 204 |
| 2329 | alarm_config | 204 | number | 7000409 |
| 2330 | alarm_config | 204 | description | VCAgent High Resolution SOAM SLM instances validation |
| 2331 | alarm_config | 204 | enabled | true |
| 2332 | alarm_config | 204 | severity | minor |
| 2333 | alarm_config | 204 | serviceAffecting | false |
| 2334 | alarm_config | 204 | extNumber | 7.0004.09 |
| 2335 | alarm_config | 204 | conditionType | VCA-MAX-SLM |
| 2336 | alarm_config | 204 | amoType | VCAGENT |
| 2337 | alarm_config | 204 | on | 0 |
| 2338 | alarm_config | 205 | id | 205 |
| 2339 | alarm_config | 205 | number | 7000415 |
| 2340 | alarm_config | 205 | description | VCAgent High Resolution SOAM SA statistics buffer full |
| 2341 | alarm_config | 205 | enabled | true |
| 2342 | alarm_config | 205 | severity | major |
| 2343 | alarm_config | 205 | serviceAffecting | false |
| 2344 | alarm_config | 205 | extNumber | 7.0004.15 |
| 2345 | alarm_config | 205 | conditionType | VCA-FULL-SA |
| 2346 | alarm_config | 205 | amoType | VCAGENT |
| 2347 | alarm_config | 205 | on | 0 |
| 2348 | alarm_config | 206 | id | 206 |
| 2349 | alarm_config | 206 | number | 7000407 |
| 2350 | alarm_config | 206 | description | VCAgent High Resolution SOAM SA instances validation |
| 2351 | alarm_config | 206 | enabled | true |
| 2352 | alarm_config | 206 | severity | minor |
| 2353 | alarm_config | 206 | serviceAffecting | false |
| 2354 | alarm_config | 206 | extNumber | 7.0004.07 |
| 2355 | alarm_config | 206 | conditionType | VCA-MAX-SA |
| 2356 | alarm_config | 206 | amoType | VCAGENT |
| 2357 | alarm_config | 206 | on | 0 |
| 2358 | alarm_config | 207 | id | 207 |
| 2359 | alarm_config | 207 | number | 7000416 |
| 2360 | alarm_config | 207 | description | VCAgent High Resolution SOAM SA Metrics statistics buffer full |
| 2361 | alarm_config | 207 | enabled | true |
| 2362 | alarm_config | 207 | severity | major |
| 2363 | alarm_config | 207 | serviceAffecting | false |
| 2364 | alarm_config | 207 | extNumber | 7.0004.16 |
| 2365 | alarm_config | 207 | conditionType | VCA-FULL-SA_M |
| 2366 | alarm_config | 207 | amoType | VCAGENT |
| 2367 | alarm_config | 207 | on | 0 |
| 2368 | alarm_config | 208 | id | 208 |
| 2369 | alarm_config | 208 | number | 7000408 |
| 2370 | alarm_config | 208 | description | VCAgent High Resolution SOAM SA Metrics instances validation |
| 2371 | alarm_config | 208 | enabled | true |
| 2372 | alarm_config | 208 | severity | minor |
| 2373 | alarm_config | 208 | serviceAffecting | false |
| 2374 | alarm_config | 208 | extNumber | 7.0004.08 |
| 2375 | alarm_config | 208 | conditionType | VCA-MAX-SA_M |
| 2376 | alarm_config | 208 | amoType | VCAGENT |
| 2377 | alarm_config | 208 | on | 0 |
| 2378 | alarm_config | 209 | id | 209 |
| 2379 | alarm_config | 209 | number | 7000421 |
| 2380 | alarm_config | 209 | description | VCAgent High Resolution TWAMP statistics buffer full |
| 2381 | alarm_config | 209 | enabled | true |
| 2382 | alarm_config | 209 | severity | major |
| 2383 | alarm_config | 209 | serviceAffecting | false |
| 2384 | alarm_config | 209 | extNumber | 7.0004.21 |
| 2385 | alarm_config | 209 | conditionType | VCA-FULL-TWAMP |
| 2386 | alarm_config | 209 | amoType | VCAGENT |
| 2387 | alarm_config | 209 | on | 0 |
| 2388 | alarm_config | 210 | id | 210 |
| 2389 | alarm_config | 210 | number | 7000420 |
| 2390 | alarm_config | 210 | description | VCAgent High Resolution TWAMP instances validation |
| 2391 | alarm_config | 210 | enabled | true |
| 2392 | alarm_config | 210 | severity | minor |
| 2393 | alarm_config | 210 | serviceAffecting | false |
| 2394 | alarm_config | 210 | extNumber | 7.0004.20 |
| 2395 | alarm_config | 210 | conditionType | VCA-MAX-TWAMP |
| 2396 | alarm_config | 210 | amoType | VCAGENT |
| 2397 | alarm_config | 210 | on | 0 |
| 2398 | alarm_config | 211 | id | 211 |
| 2399 | alarm_config | 211 | number | 7000423 |
| 2400 | alarm_config | 211 | description | VCAgent High Resolution Shaper statistics buffer full |
| 2401 | alarm_config | 211 | enabled | true |
| 2402 | alarm_config | 211 | severity | major |
| 2403 | alarm_config | 211 | serviceAffecting | false |
| 2404 | alarm_config | 211 | extNumber | 7.0004.23 |
| 2405 | alarm_config | 211 | conditionType | VCA-FULL-SHAPER-V2 |
| 2406 | alarm_config | 211 | amoType | VCAGENT |
| 2407 | alarm_config | 211 | on | 0 |
| 2408 | alarm_config | 212 | id | 212 |
| 2409 | alarm_config | 212 | number | 7000422 |
| 2410 | alarm_config | 212 | description | VCAgent High Resolution Shaper instances validation |
| 2411 | alarm_config | 212 | enabled | true |
| 2412 | alarm_config | 212 | severity | minor |
| 2413 | alarm_config | 212 | serviceAffecting | false |
| 2414 | alarm_config | 212 | extNumber | 7.0004.22 |
| 2415 | alarm_config | 212 | conditionType | VCA-MAX-SHAPER-V2 |
| 2416 | alarm_config | 212 | amoType | VCAGENT |
| 2417 | alarm_config | 212 | on | 0 |
| 2418 | alarm_config | 213 | id | 213 |
| 2419 | alarm_config | 213 | number | 7000425 |
| 2420 | alarm_config | 213 | description | VCAgent High Resolution Port statistics buffer full |
| 2421 | alarm_config | 213 | enabled | true |
| 2422 | alarm_config | 213 | severity | major |
| 2423 | alarm_config | 213 | serviceAffecting | false |
| 2424 | alarm_config | 213 | extNumber | 7.0004.25 |
| 2425 | alarm_config | 213 | conditionType | VCA-FULL-PORT |
| 2426 | alarm_config | 213 | amoType | VCAGENT |
| 2427 | alarm_config | 213 | on | 0 |
| 2428 | alarm_config | 214 | id | 214 |
| 2429 | alarm_config | 214 | number | 7000424 |
| 2430 | alarm_config | 214 | description | VCAgent High Resolution Port instances validation |
| 2431 | alarm_config | 214 | enabled | true |
| 2432 | alarm_config | 214 | severity | minor |
| 2433 | alarm_config | 214 | serviceAffecting | false |
| 2434 | alarm_config | 214 | extNumber | 7.0004.24 |
| 2435 | alarm_config | 214 | conditionType | VCA-MAX-PORT |
| 2436 | alarm_config | 214 | amoType | VCAGENT |
| 2437 | alarm_config | 214 | on | 0 |
| 2438 | alarm_config | 215 | id | 215 |
| 2439 | alarm_config | 215 | number | 7000428 |
| 2440 | alarm_config | 215 | description | VCAgent High Resolution SFP statistics buffer full |
| 2441 | alarm_config | 215 | enabled | true |
| 2442 | alarm_config | 215 | severity | major |
| 2443 | alarm_config | 215 | serviceAffecting | false |
| 2444 | alarm_config | 215 | extNumber | 7.0004.28 |
| 2445 | alarm_config | 215 | conditionType | VCA-FULL-SFP |
| 2446 | alarm_config | 215 | amoType | VCAGENT |
| 2447 | alarm_config | 215 | on | 0 |
| 2448 | alarm_config | 216 | id | 216 |
| 2449 | alarm_config | 216 | number | 7000429 |
| 2450 | alarm_config | 216 | description | VCAgent High Resolution System Health statistics buffer full |
| 2451 | alarm_config | 216 | enabled | true |
| 2452 | alarm_config | 216 | severity | major |
| 2453 | alarm_config | 216 | serviceAffecting | false |
| 2454 | alarm_config | 216 | extNumber | 7.0004.29 |
| 2455 | alarm_config | 216 | conditionType | VCA-FULL-SYSTEM-HEALTH |
| 2456 | alarm_config | 216 | amoType | VCAGENT |
| 2457 | alarm_config | 216 | on | 0 |
| 2458 | alarm_config | 217 | id | 217 |
| 2459 | alarm_config | 217 | number | 19000101 |
| 2460 | alarm_config | 217 | description | One or more certificates is about to expire |
| 2461 | alarm_config | 217 | enabled | true |
| 2462 | alarm_config | 217 | severity | minor |
| 2463 | alarm_config | 217 | serviceAffecting | false |
| 2464 | alarm_config | 217 | extNumber | 19.0001.01 |
| 2465 | alarm_config | 217 | conditionType | EXPIRING |
| 2466 | alarm_config | 217 | amoType | CERTIFICATE.EXPIRING |
| 2467 | alarm_config | 217 | on | 0 |
| 2468 | alarm_config | 218 | id | 218 |
| 2469 | alarm_config | 218 | number | 19000102 |
| 2470 | alarm_config | 218 | description | One or more certificates has expired |
| 2471 | alarm_config | 218 | enabled | true |
| 2472 | alarm_config | 218 | severity | major |
| 2473 | alarm_config | 218 | serviceAffecting | false |
| 2474 | alarm_config | 218 | extNumber | 19.0001.02 |
| 2475 | alarm_config | 218 | conditionType | EXPIRED |
| 2476 | alarm_config | 218 | amoType | CERTIFICATE.EXPIRED |
| 2477 | alarm_config | 218 | on | 0 |
| 2478 | alarm_status | 1 | id | 1 |
| 2479 | alarm_status | 1 | number | 8000001 |
| 2480 | alarm_status | 1 | active | false |
| 2481 | alarm_status | 1 | lastChange | 0-1-1,0:0:0.0 |
| 2482 | alarm_status | 1 | on | 0 |
| 2483 | alarm_status | 2 | id | 2 |
| 2484 | alarm_status | 2 | number | 8000002 |
| 2485 | alarm_status | 2 | active | false |
| 2486 | alarm_status | 2 | lastChange | 0-1-1,0:0:0.0 |
| 2487 | alarm_status | 2 | on | 0 |
| 2488 | alarm_status | 3 | id | 3 |
| 2489 | alarm_status | 3 | number | 8000004 |
| 2490 | alarm_status | 3 | active | false |
| 2491 | alarm_status | 3 | lastChange | 0-1-1,0:0:0.0 |
| 2492 | alarm_status | 3 | on | 0 |
| 2493 | alarm_status | 4 | id | 4 |
| 2494 | alarm_status | 4 | number | 8000005 |
| 2495 | alarm_status | 4 | active | true |
| 2496 | alarm_status | 4 | lastChange | 1970-6-22,22:29:7.0,-7:0 |
| 2497 | alarm_status | 4 | on | 0 |
| 2498 | alarm_status | 5 | id | 5 |
| 2499 | alarm_status | 5 | number | 8000101 |
| 2500 | alarm_status | 5 | active | false |